State University of New York at Buffalo
Development of Instrumentation for Laser-Induced Breakdown Spectroscopy and Laser Ablation Molecular Isotopic Spectrometry
Abstract
dc:description.abstractLaser-induced breakdown spectroscopy (LIBS) and laser ablation molecular isotopic spectrometry (LAMIS) are optical analysis techniques that allow for measurement of a sample’s elemental and isotopic composition, respectively. In both techniques, a laser is focused onto the surface of a sample, resulting in ablation of sample and formation of a laser-induced plasma (LIP) from which emission is detected. Although LIBS is widely used as an analytical technique, there are limitations associated with the price of equipment, portability, and shot-to-shot variations that require continued study. These limitations have also limited the applicability of LAMIS to commercial devices. Here, we explore techniques to combat these limitations using novel instrumental techniques that are cost-effective and permissible for portability. In LIBS and LAMIS experiments, temporal gating is used to detect emission at the best possible signal-to-background (S/B) and signal-to-noise (S/N) ratios. Typically, intensified charge coupled devices (ICCDs) are used to enable temporal gating, however they are cost intensive and not fit for hand-held use. In Chapter 2, a digital micromirror array (DMMA) is used as an external temporal gating device with a traditional CCD, offering a cheaper alternative to the ICCD. The experiments demonstrate that the DMMA temporal gating speed is approximately 160 ns which is compatible with LIBS and LAMIS experiments. The DMMA, being composed of over 1-million micromirrors that can be individually programed. This makes it possible to selectively sample various regions of the LIP, which results in ability to optimize detection of location-dependent spectral features. To improve LIBS signals, previous studies have used microwaves to re-excite electrons within the plasma and extend its lifetime. LIPs are inherently transient, lasting only a few microseconds. By applying microwaves to the LIP, electrons are re-excited, resulting in collisions that re-excite ground-state species. This results in a LIP that can be sustained up to a few milliseconds, which allows for increased detection time, improving S/N. Previously, application of microwaves to a LIP has been performed using either a microwave cavity or an applicator that simply act as transmission lines. In Chapter 3, a linear microwave microstrip resonator is designed and evaluated as a method to incorporate microwaves into a LIP. The design of the resonator optimizes power coupling and electric and magnetic field strengths with a goal of improving microwave application over previously developed techniques. An additional attribute to the design is that the amount of microwave energy absorbed by the plasma can be monitored via capacitive coupling of a counter electrode that is connected to a detector. In addition to the microwave microstrip resonator, a microwave microstrip transmission line is evaluated for LIBS and LAMIS application in Chapter 4 and Chapter 5, respectively. In these sections, the applications of microwaves to the LIP are shown to enhance atomic, ionic, and molecular emission. In addition, Chapter 4 contains an evaluation of the microwaves on the LIP. Future applications of these methods and development of new methods are discussed.
Degree
thesis:*- Grantor dc:publisher
- State University of New York at Buffalo
- Year dc:date.issued
- 2024
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Williams, Kelsey; 0000-0003-2070-6361
- Contributors dc:contributor
-
- Ray, Steven
- Chemistry
Subjects
dc:subject × 1Rights
dc:rights- Statement dc:rights
-
- Copyright retained by author. Users of works found in University at Buffalo Institutional Repository (UBIR) are responsible for identifying and contacting the copyright owner for permission to reuse. University at Buffalo Libraries do not manage rights for copyright-protected works and cannot assist with permissions.
- Language dc:language
- eng
Identifiers
dc:identifier.*- Handle dc:identifier
- http://hdl.handle.net/10477/89340