State University of New York at Buffalo
Enabling Sensitive and Robust Characterization of Protein Therapeutics and Biomarkers in Biomatrices Through Novel LC-MS-Based Strategies
Abstract
dc:description.abstractThe critical importance of measuring biotherapeutics and biomarkers in circulation and tissues has been very well appreciated. Such quantitative investigation of biotherapeutics and biomarkers in preclinical and clinical settings affords essential information to evaluate drug safety and efficacy, to direct therapeutic and engineering efforts, and to pre-diagnose, stage and track the progression of the disease. Recently, LC-MS-based strategies has emerged as a promising technique for quantitative analysis of protein biotherapeutics and biomarkers in biomatrices. Compared to the traditional ligand binding assay (LBA), LC-MS holds several advantages including high specificity, broad dynamic range, good multiplexing ability with cost-effective and rapid method development. However, it still has a number of technical challenges which need to be properly addressed, such as the insufficient sensitivity. Additionally, sample preparation and method development need to be systemically investigated and optimized to enable a reliable and robust quantification, especially for specific matrix types such as Formalin-Fixed Paraffin-Embedded (FFPE) tissues. Therefore, several novel LC-MS strategies were developed to address those issues. To improve the sensitivity, we successfully applied immunoaffinity enrichment to MS analysis. With the developed multiplexed immunoaffinity LC-MS/MS (multi-IA-LC-MS) assay, we were able to measure three critical adipokines, leptin, resistin, and adiponectin, simultaneously in human plasma with the lower limits of quantification (LOQ) of 0.5, 0.5, and 50 ng/mL respectively, which significantly outperformed than the other reported LC-MS based methods for those three targets with improved sensitivity. Other than antibody-based enrichment, antibody-free enrichment (i.e., solid phase extraction with mixed cation exchange) was demonstrated to be able to efficiently reduce the matrix components. When integrated with trapping-µLC FAIMS/SRM-MS system, the established workflow was able to accurately quantify the absolute level of fifteen prominent gluten immunogenic peptides (GIP) in urine with LOQ at pg/mL level with enhanced throughput of the analysis. We also systemically evaluated the performance of a narrow-window-isolation-SRM (NWI-SRM) strategy. The NWI-SRM applied an improved resolution in Q1 on triple quadruple mass spectrometer, which could improve the selectivity from MS end directly. Compared to the traditional unit-resolution-SRM, we observed a 3- to 100- fold signal to noise ratio (S/N) improvement and 3- to 6- fold LOQ improvement in the quantification of mAbs in plasma and tissues, which indicated an advanced sensitivity...
Degree
thesis:*- Grantor dc:publisher
- State University of New York at Buffalo
- Year dc:date.issued
- 2024
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Pu, Jie
- Contributors dc:contributor
-
- Qu, Jun
- Pharmaceutical Sciences
Subjects
dc:subject × 1Rights
dc:rights- Statement dc:rights
-
- Copyright retained by author. Users of works found in University at Buffalo Institutional Repository (UBIR) are responsible for identifying and contacting the copyright owner for permission to reuse. University at Buffalo Libraries do not manage rights for copyright-protected works and cannot assist with permissions.
- Language dc:language
- eng
Identifiers
dc:identifier.*- Handle dc:identifier
- http://hdl.handle.net/10477/89354