State University of New York at Buffalo
Does a Priming Warm-Up Influence the Incidence of V̇O2pl During a Ramp Test and Verification Phase?
Abstract
dc:description.abstractObjective: This study aimed to compare two different warm-up protocols (normal vs. priming) on the occurrence of oxygen plateau (V̇O2pl) during a ramp test. A secondary aim was to compare the cardiopulmonary responses during the ramp test and subsequent verification phase. Methods: Eleven experienced recreational cyclists performed experimental visits. The first visit required a normal warm-up (cycling at 50W for 10 minutes) followed by the ramp test (30 W.min-1) and biphasic supramaximal verification phase with 30-minute rest between tests. The second visit was similar, except a priming warm-up (cycling at 50 W for 4 minutes, increasing to 70% difference between the gas exchange threshold and maximum work rate for 6 minutes) was employed. Results: As planned, during the warm-up the priming group experienced greater blood lactate (normal: 1.4 ± 0.5 mmol.L-1; primed: 10.3 ± 3.4 mmol.L-1), heart rate (normal: 113 ± 10 bpm; primed: 173.9 ± 10.8 bpm), and V̇O2 (normal: 21.7 ± 2.5 mL.kg-1.min-1; primed: 47.9 ± 3.7 mL.kg-1.min-1) compared to normal (p < 0.001). However, the incidence rate of V̇O2pl during the ramp test was the same between groups (73%) and maximal oxygen uptake was not different between groups after the ramp test and verification phase (p > 0.05). Overall and exercise domain specific oxygen kinetics was not different between groups during the ramp test (p > 0.05). The verification phase confirmed V̇O2max in 91% of the normal and 100% of the priming group. Conclusion: Our hypothesis that a priming warm-up facilitates the incidence rate of V̇O2pl during a ramp test is not supported by our findings. The physiological responses were similar between the different warm-up protocols during the ramp test and verification phase, indicating that a priming warm-up is not necessary. The verification phase following a ramp test remains a prudent option when determining a ‘true’ V̇O2max is required.
Degree
thesis:*- Grantor dc:publisher
- State University of New York at Buffalo
- Year dc:date.issued
- 2024
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Qiao, JianBo; 0009-0009-6035-0065
- Contributors dc:contributor
-
- Pryor, J. Luke
- Exercise and Nutrition Sciences
Subjects
dc:subject × 2Rights
dc:rights- Statement dc:rights
-
- Copyright retained by author. Users of works found in University at Buffalo Institutional Repository (UBIR) are responsible for identifying and contacting the copyright owner for permission to reuse. University at Buffalo Libraries do not manage rights for copyright-protected works and cannot assist with permissions.
- Language dc:language
- eng
Identifiers
dc:identifier.*- Handle dc:identifier
- http://hdl.handle.net/10477/89378