Back to search

State University of New York at Buffalo

Development of Ion Mirror and Detection Region Configurations for Distance-of-Flight Mass Spectrometry

Abstract

dc:description.abstract

Distance-of-flight mass spectrometry (DOFMS) is a velocity-based mass separation method that is a complement to traditional time-of-flight mass spectrometry (TOFMS). TOFMS measures ion mass-to-charge ratios (m/z) by measuring the time required for an ion to traverse a flight distance. DOFMS spatially-separates ions according to m/z and measures the m/z of each ion based on the distance traveled within a specific time. The development and implementation of DOFMS is relatively new in the field of mass spectrometry. Initial characterization has previously been reported with several array detectors and various sample introductory methods. The work in this dissertation will explore how the similarities between TOFMS and DOFMS can be used as a means to better understand and advance techniques used in glow discharge (GD)-DOFMS. Mass resolving power attained in DOFMS is governed by the fact that ions of the same m/z will possess a range of initial energies at the start of the experiment. If left uncorrected, differences in initial energy will lead to different flight distances, degrading mass resolving power. To overcome this problem, an ion mirror is used to compensate for these initial ion energy differences. Previously DOFMS only explored a single-stage ion mirror. In principle, a dual-stage ion mirror should better compensate for energy dispersion of the ions analyzed by the DOFMS, and thus provide greater mass resolving powers. Chapter 2 explores the first dual-stage ion mirror reported for DOFMS. Improvements in expected mass resolving power were simulated and confirmed experimentally for isotopes of copper, zinc, tin and lead. The dual-stage ion mirror improved mass resolving power over comparable literature values between 20-41%. In Chapter 3, a novel focusing strategy in the detection region was explored. A dual-stage detection scheme that exploits space-focus concepts in DOFMS was theoretically described, and several regions were designed, constructed, and evaluated as a technique to better compensate for the height of the ion beam that enters the DOF detection region. Simulations showed a significant improvement in mass resolving power when the dual-stage detection region was employed. An experimentally modified dual-stage detection region demonstrated mass resolving power improvement up to 69% for tin isotopes in addition to the dual-stage ion mirror alone. Future changes to the lengthen the dual-stage detection field-free region should result in further improvements…

Degree

thesis:*
Grantor dc:publisher
State University of New York at Buffalo
Year dc:date.issued
2024

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Jensen, Eric; 0000-0003-1219-9187
Contributors dc:contributor
  • Ray, Steven
  • Chemistry

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • Copyright retained by author. Users of works found in University at Buffalo Institutional Repository (UBIR) are responsible for identifying and contacting the copyright owner for permission to reuse. University at Buffalo Libraries do not manage rights for copyright-protected works and cannot assist with permissions.
Language dc:language
eng

Identifiers

dc:identifier.*
Handle dc:identifier
http://hdl.handle.net/10477/89632

Chain of custody

source
Harvested from
Buffalo
Base URL
ubir.buffalo.edu/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Jensen, Eric; 0000-0003-1219-9187. Development of Ion Mirror and Detection Region Configurations for Distance-of-Flight Mass Spectrometry. State University of New York at Buffalo, 2024. http://hdl.handle.net/10477/89632