Experimental and Numerical Evaluation of the Performance of URM Walls Retrofitted with Steel Strong Backs Under Out-of-Plane Seismic Loads

Abstract

dc:description.abstract

Unreinforced masonry (URM) buildings are rather vulnerable as they can fail in a catastrophic manner when subjected to earthquake loads due to their large mass, low tensile strength, and brittleness. To address their vulnerability and improve their seismic performance, a number of retrofit methods have been employed in areas of high seismicity such as California, with the most common method being the installation of steel strong backs with the use of adhesive anchors. However, the guidelines typically followed are often prescriptive and lack rigorous validation from three-dimensional dynamic tests and detailed finite element models. This dissertation investigates experimentally and numerically the seismic performance of existing URM walls retrofitted with a steel strongback. Initially, a series of static pullout tests were carried out to evaluate the influence of the anchor geometry, embedment length, pre-existing masonry damage, if any, and the test setup on the capacity of an anchor. The obtained test data are utilized to develop a phenomenological bond-slip relation for adhesive anchors installed on masonry walls. Following the static pullout tests, the cyclic response of anchors installed on five 5-ft tall multi-wythe unretrofitted URM walls was evaluated under out-of-plane dynamic loading. The test results provide data on the effect of the crack opening and location on the capacity of the anchor. In the last phase of the testing campaign, four 10-ft tall URM walls, retrofitted with steel strong backs, were tested under cyclic loading to investigate the interaction between the URM walls and the strong back. The test results allow the quantification of the influence of the strong back size, anchor layout, and boundary conditions on the strength and failure pattern of the retrofitted walls. The test results are used to evaluate a detailed nonlinear three-dimensional finite element modeling scheme developed to model the response of URM walls retrofitted with steel strong backs. The scheme combines solid and interface elements to simulate the behavior of the masonry units, mortar, and steel strong back, while the bond-slip relation developed in this study is used to simulate the connection of the anchors to the masonry wall. The numerical model, calibrated with the data from extensive material tests on small masonry assemblies, is used to simulate the dynamic tests of the 10-ft retrofitted walls. The comparison of the numerical and experimental data indicates that the FE models can simulate the seismic performance of URM structures retrofitted with strong backs, and can capture the nonlinear behavior of each component and their interaction. The validated model is used in a parametric study to investigate the effect of material and design parameters on the response of these structures.

Degree

thesis:*
Grantor dc:publisher
State University of New York at Buffalo
Year dc:date.issued
2024

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Raman, Rahul; 0000-0002-6133-1749
Contributors dc:contributor
  • Stavridis, Andreas
  • Civil, Structural and Environmental Engineering

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • Copyright retained by author. Users of works found in University at Buffalo Institutional Repository (UBIR) are responsible for identifying and contacting the copyright owner for permission to reuse. University at Buffalo Libraries do not manage rights for copyright-protected works and cannot assist with permissions.
Language dc:language
eng

Identifiers

dc:identifier.*
Handle dc:identifier
http://hdl.handle.net/10477/89764

Chain of custody

source
Harvested from
Buffalo
Base URL
ubir.buffalo.edu/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Raman, Rahul; 0000-0002-6133-1749. Experimental and Numerical Evaluation of the Performance of URM Walls Retrofitted with Steel Strong Backs Under Out-of-Plane Seismic Loads. State University of New York at Buffalo, 2024. http://hdl.handle.net/10477/89764