State University of New York at Buffalo
Comparing Friction and Slot Dimensional Integrity of In-House 3D-Printed Orthodontic Brackets to Injection-Molded Alternatives
Abstract
dc:description.abstractIntroduction: Recently, advanced glass-filled hybrid ceramic resins have entered the in-office 3D printing space. Intended for use as a permanent crown material, BEGO VarseoSmile Crown Plus (VSC), (BEGO GmbH & Co. KG, Bremen, Germany), has been the focus of recent orthodontic literature as a possible material for in-house bracket production. Early studies show favorable generalized properties of the material, such as strength and color stability. With growing support, there is more to learn about the mechanical properties of this material before the material can be deemed suitable for orthodontics. Objectives: The objectives of this study are to determine if 3D-printed orthodontic brackets made of VSC have comparable frictional properties and dimensional stability to contemporary injection-molded alternatives. Methods: 32 copies of Dentaurum Discovery Pearl (Dentaurum GmbH & Co. KG, Ispringen, Germany) maxillary right canine bracket STL with 0° torque and 8° angulation and distogingival hooks were 3D-printed with Form 3B+ 3D-printer (Formlabs, Springville, MA) with the slot perpendicular to the build platform and direction of layer deposition. Each bracket model was scaled up in size by a multiplier of 1.177 to account for material shrinkage. AI-generated support struts were created, and brackets were 3D-printed at a 50µm layer thickness from VSC material. The brackets were post-processed using 99% isopropyl alcohol and 80 µm glass beads. Slot inciso-gingival height and two angular measurements were collected from each bracket using a digital microscope and ImageJ Fiji (National Institutes of Health, Bethesda, MD). Identical measurements were taken on 32 metal (Victory Series, 3M, St Paul, MN) and ceramic (Clarity Advanced, 3M) injection-molded brackets. The 96 brackets were divided into six equal groups separated by bracket material and wire type and underwent three rounds of friction testing with 0.019x0.025” stainless-steel and nickel-titanium wires using a Universal Testing Machine. Static frictional force was recorded, and the brackets were re-measured for dimensional comparisons. Select group-representative brackets were sectioned and underwent scanning electron microscopy for qualitative analysis...
Degree
thesis:*- Grantor dc:publisher
- State University of New York at Buffalo
- Year dc:date.issued
- 2024
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Baker, John; 0009-0003-7221-7567
- Contributors dc:contributor
-
- Gurav, Ashish
- Orthodontics
Subjects
dc:subject × 6Rights
dc:rights- Statement dc:rights
-
- Copyright retained by author. Users of works found in University at Buffalo Institutional Repository (UBIR) are responsible for identifying and contacting the copyright owner for permission to reuse. University at Buffalo Libraries do not manage rights for copyright-protected works and cannot assist with permissions.
- Language dc:language
- eng
Identifiers
dc:identifier.*- Handle dc:identifier
- http://hdl.handle.net/10477/89840