Back to search

State University of New York at Buffalo

Bolted Splice Details for Composite Plate Shear Walls-Concrete Filled

Abstract

dc:description.abstract

Composite Plate Shear Walls—Concrete Filled (C-PSW/CF) consist of two steel faceplates with concrete infill sandwiched between them. This structural system has garnered national attention for implementation in non-seismic regions, where bolted connections are preferred over welded ones. This research investigates bolted splice details for C-PSW/CF to facilitate their use in such regions. Objectives include assessing the applicability of existing AISC strength equations, comparing splice details, evaluating stiffness equations, understanding ultimate behavior, and validating numerical models. The first part of the research involved testing and analyzing C-PSW/CF components through an experimental program with six tension and six shear tests on various splice designs, including blind bolts, Shuriken details, and through rods with pipe-sleeves. All splice details met the design strength per AISC equations. Proposed simplified spring models successfully replicated the hysteresis curves and modeled the behavior of tension specimens, including friction sliding, bearing, net and gross section yielding, and concrete behaviors. Finite element models accurately captured the behavior of tension and shear specimens under monotonic and cyclic loading, showing significant reduction in friction forces as bolt hole elongation increased, indicating the impact of bolt hole deformation on friction development. This work provides valuable insights into the expected behavior of bolted C-PSW/CF components under various design limit states. The second part involved testing and analyzing a large-scale T-shaped C-PSW/CF specimen with bolted splices. The horizontal splice was designed to develop approximately 60% of the faceplate yield strength in tension, while vertical splices used steel component and composite section approaches for slip-critical design. A proposed simplified method calculated the target flexural strength of the horizontal splice to develop bearing strength of 2.4dtFu and 3.0dtFu. The tested wall achieved the target flexural strength and maintained at least 80% of peak strength until 2.4% positive drift and -4.3% negative drift, with no slip observed in vertical splices. Finite element models of the wall specimen were developed to investigate its inelastic behavior. Monotonic pushover analyses assessed the ultimate behavior, while cyclic loading analyses compared inelastic behavior with test results. This research demonstrated the satisfactory inelastic behavior of a bolted C-PSW/CF under axial and cyclic lateral loads that can be obtained when designed such that the bolts in horizontal splices are governed by bearing strength and the bolts in vertical splices are governed by slip-critical resistance.

Degree

thesis:*
Grantor dc:publisher
State University of New York at Buffalo
Year dc:date.issued
2024

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Liu, Jia-Hau; 0009-0003-9608-1932
Contributors dc:contributor
  • Bruneau, Michel
  • Civil, Structural and Environmental Engineering

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • Copyright retained by author. Users of works found in University at Buffalo Institutional Repository (UBIR) are responsible for identifying and contacting the copyright owner for permission to reuse. University at Buffalo Libraries do not manage rights for copyright-protected works and cannot assist with permissions.
Language dc:language
eng

Identifiers

dc:identifier.*
Handle dc:identifier
http://hdl.handle.net/10477/89849

Chain of custody

source
Harvested from
Buffalo
Base URL
ubir.buffalo.edu/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Liu, Jia-Hau; 0009-0003-9608-1932. Bolted Splice Details for Composite Plate Shear Walls-Concrete Filled. State University of New York at Buffalo, 2024. http://hdl.handle.net/10477/89849