State University of New York at Buffalo
Cathodic Voltage-Controlled Electrical Stimulation as a Treatment for MRSA Sourced Periprosthetic Joint Infection on Titanium Alloy Ti64, Cobalt-Chromium-Molybdenum, and Polyethylene
Abstract
dc:description.abstractPeriprosthetic joint infections (PJI) are a devastating and costly complication that can arise following a total joint arthroplasty. They are difficult to properly diagnose and, moreover, only a minimal pathogenic presence is required to source an infection. Methicillin-resistant Staphylococcus aureus (MRSA) is a primary causative agent for infections of this nature. The virulence of this biofilm forming pathogen and concern surrounding antibiotic resistance development make this microorganism particularly problematic. Previous studies have shown cathodic voltage-controlled electrical stimulation (CVCES) applied to commercially pure titanium (cpTi) produces reductions in MRSA biofilms on the surface of the metal as well as planktonic bacteria suspended in the surrounding media. The corresponding increase in pH of the electrolyte resulting from the faradaic process induced by CVCES is believed to be a critical component responsible for the observed biofilm reductions. Most modern joint replacement constructs incorporate the use of a non-conductive material in their design with ultra-high molecular weight polyethylene (UHMWPE) being among the most popular. This study evaluated CVCES of titanium alloy Ti64, Cobalt Chromium Molybdenum (CoCrMo), and a galvanic pairing of the two as a means to prevent and eradicate MRSA biofilm formation on the surface of the metal alloys as well as on the surface of an adjacent non-conductive UHMWPE sample. Evaluations included the use of vancomycin to assess the possible synergy between CVCES and the antibiotic. Prevention studies were performed by applying CVCES of two separate magnitudes for either 2 or 24 hours with eradication studies conducted using up to three different magnitudes for a duration of 2, 5, or 24 hours. Treatment conditions assessed included CVCES paired with vancomycin, CVCES alone, vancomycin alone, and the control which did not receive an antibiotic dosage or any electrical stimulation. Prevention results presented reductions measuring ~ 5 log in MRSA biofilm on the surface of the UHMWPE as well as on the metal alloys when compared to their respective Controls. Eradication trials displayed reductions of the preformed MRSA biofilm of ~ 7 log on the surface of the UHMWPE. Planktonic bacteria suspended in the growth media was also highly susceptible to antibacterial effects of CVCES for both treatment studies. The ability to prevent and eradicate MRSA biofilm on the surface of these conductive and non-conductive materials greatly increases the versatility and promise of CVCES to become an impactful clinical therapy for implant associated infections.
Degree
thesis:*- Grantor dc:publisher
- State University of New York at Buffalo
- Year dc:date.issued
- 2024
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- McPhillips, Kevin
- Contributors dc:contributor
-
- Ehrensberger, Mark
- Biomedical Engineering
Subjects
dc:subject × 1Rights
dc:rights- Statement dc:rights
-
- Copyright retained by author. Users of works found in University at Buffalo Institutional Repository (UBIR) are responsible for identifying and contacting the copyright owner for permission to reuse. University at Buffalo Libraries do not manage rights for copyright-protected works and cannot assist with permissions.
- Language dc:language
- eng
Identifiers
dc:identifier.*- Handle dc:identifier
- http://hdl.handle.net/10477/89898