State University of New York at Buffalo
Method Development of Liquid Chromatography Tandem Mass Spectrometry and Matrix Assisted Laser Desorption/Ionization for the Analysis of Biological Analytes
Abstract
dc:description.abstractThis dissertation stems around the use of mass spectrometry as a detector for small molecules. In this dissertation two different ionization techniques were used for analysis. Both matrix assisted laser desorption/ionization (MALDI) and electrospray ionization (ESI) were used before being entered into a mass spectrometer. Four different mass spectrometer types were used including Fourier transform ion cyclotron resonance mass spectrometer (FTICR MS), linear ion trap mass spectrometer (LIT MS), Orbitrap, and a triple quadrupole mass spectrometer (QqQ MS). The first study was creating a quantitative MALDI mass spectrometry method for peptides. In this application dried droplet was used to spot varying concentrations of leucine enkephalin (LE) mixed with gluten exorphin B5 (B5) as an internal standard. An optimized dried droplet method was created with a siloxane film grid and a drying step with a freeze dryer. For the matrix application DHB and CHCA solutions were optimized for solvent and concentration. For matrix application sublimation length was optimized. Calibration curves were created of intensity or peak area of LE/B5 with concentrations of 200 to 1000 ppb. The calibration curves were processed in magnitude-mode and absorption-mode and were relatively linear with R2 of 0.88 to 0.93. The second project used ESI with the development of a liquid chromatography mass spectrometry (LC-MS) method on an LTQ mass spectrometer. This method was an untargeted workflow looking for metabolic profiles of methanol extracts of tissue biopsies from a new pathology technique called molecular preservation by extraction and fixation (mPREF). An LC gradient was created for enlarged prostate biopsy extracts and rat placenta extracts. A solid phase extraction (SPE) method was established for sample clean up prior to injection on the LC-MS method. A 25 minute gradient was established with solvents of 0.1% formic acid and methanol. This method was transferred to a high resolution mass spectrometer the Orbitrap and optimized to create a liquid chromatography tandem mass spectrometry (LC-MS/MS) method to create metabolic profiles. With this method different features were identified to create metabolic profiles using Compound Discoverer. The next project expanded on the previous developed SPE LC-MS/MS method on the Orbitrap. This method was applied to bladder cancer extracts. Seven cases were used to create metabolic profiles. These profiles were processed with Compound Discoverer to identify possible features or molecular formulas…
Degree
thesis:*- Grantor dc:publisher
- State University of New York at Buffalo
- Year dc:date.issued
- 2024
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Izydorczak, Alexandra; 0000-0002-7079-5270
- Contributors dc:contributor
-
- Wood, Troy
- Chemistry
Subjects
dc:subject × 1Rights
dc:rights- Statement dc:rights
-
- Copyright retained by author. Users of works found in University at Buffalo Institutional Repository (UBIR) are responsible for identifying and contacting the copyright owner for permission to reuse. University at Buffalo Libraries do not manage rights for copyright-protected works and cannot assist with permissions.
- Language dc:language
- eng
Identifiers
dc:identifier.*- Handle dc:identifier
- http://hdl.handle.net/10477/89903