State University of New York at Buffalo
Strength of Prestressed Concrete Girders with Bonded and Unbonded Strands
Abstract
dc:description.abstractThe use of bonded and unbonded strands together (combined strands) is a novel reinforcement condition that can facilitate girder splicing, segmental construction, strand monitoring, and replacement during the service life for prestressed concrete members. There are two challenges associated with the use of unbonded or combined strands: 1) flexural analysis requires displacement compatibility due to lack of bond between concrete and strands, and predicting the displacement of concrete structures near failure may be unreliable, and 2) the presence of post-tensioning ducts in thin webs and the subsequent reduction of web area may impact the shear and torsional capacity. This dissertation used analytical methods to understand the flexural, shear, and torsional behavior of prestressed girders with unbonded and combined strands to address these challenges. The analytical methods were validated and calibrated with test data from a companion study. Flexure analyses using fiber-based beam elements were performed on girders that represent bridge elements in practice. The results of the analyses indicated that the flexural strength linearly increases with the ratio of bonded prestressed or reinforcement area to the total reinforcement area. An increase in the length of the constant moment region led to an increase in unbonded strand stress and consequently the flexural strength. Comparisons of the analysis results to AASHTO LRFD Bridge Design Specifications (BDS) predictions showed that AASHTO can overestimate the strength of members without any bonded reinforcement, and that the AASHTO equation for members with unbonded strands can predict the unbonded strand stress for members with combined strands. Modifications to AASHTO LRFD BDS were proposed for members with unbonded and combined strands based on a scaled plastic hinge length. A comparison of existing flexure strength prediction methods to a test database compiled from the literature indicated poor accuracy and a large scatter in predictions. Shear analyses were performed using two-dimensional nonlinear finite element analyses based on the modified compression field theory. The analysis results showed that the presence of ducts reduced shear strength and the reduction in capacity for grouted and ungrouted ducts were similar. For continuous members, the shear strengths calculated according to the AASHTO LRFD BDS significantly varied depending on the location of the web strands within the cross-section and the location at which the strengths were estimated. The analysis results showed that this variation is not warranted…
Degree
thesis:*- Grantor dc:publisher
- State University of New York at Buffalo
- Year dc:date.issued
- 2024
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Jung, Mi Jin; 0009-0004-9667-1649
- Contributors dc:contributor
-
- Okumus, Pinar
- Civil, Structural and Environmental Engineering
Subjects
dc:subject × 1Rights
dc:rights- Statement dc:rights
-
- Copyright retained by author. Users of works found in University at Buffalo Institutional Repository (UBIR) are responsible for identifying and contacting the copyright owner for permission to reuse. University at Buffalo Libraries do not manage rights for copyright-protected works and cannot assist with permissions.
- Language dc:language
- eng
Identifiers
dc:identifier.*- Handle dc:identifier
- http://hdl.handle.net/10477/89994