State University of New York at Buffalo
Durability Investigation on Oxygen-Ion Conducting Solid Oxide Electrolysis Cells for High Temperature Electrolysis of Water
Abstract
dc:description.abstractHigh temperature electrolysis of water using solid oxide electrochemical cells (SOEC) is a promising technology for hydrogen production with high energy efficiency and may promote decarbonization when coupled with renewable energy sources and excess heat from nuclear reactors. Over the past several decades there have been extensive scientific and engineering studies on cell materials and degradation behaviors that have greatly improved current density, decreased total resistance, and lowered degradation rates. Although the technology is now at a near commercial level, maintaining consistency in cell testing and minimizing variance in practical testing environments is an often overlooked but crucial topic. To promote high quality data collection, testing procedures and balance of plant component details are extremely important to consider. This work discusses some key factors affecting the reproducibility of practical SOEC testing on the button cell level, namely current collection layers, cell sealing procedures, the reliability of steam and hydrogen delivery systems, cell testing fixture design, and reduction procedures. To provide a baseline and a level of standardization for the SOEC community, this work also discloses details of the standard operating procedure and techniques adopted for o-SOEC testing at Idaho National Laboratory (INL). Secondly, commercial deployment of this technology critically depends on the long-term performance and durability of SOEC cells/stacks, especially under dynamic operations to withstand the intermittency of renewable energy. Herein, SOEC operation was conducted under galvanodynamic conditions and compared with galvanostatic cells to examine the effect on degradation behavior at an average current density of -0.75 A cm-2 at 750 °C. While dynamic operation shows no significant impact on the overall degradation rates compared to constant current operation, minor performance improvement was observed at potentials above 1.5 V when switched to galvanodynamic mode. The relatively lower overpotential during dynamic operation could not be explained by the negligible changes in the electrochemical impedance or cell temperature. Multiphysics modeling reveals that the oxygen partial pressure (PO2) in the electrolyte oscillates with the alternating current density under dynamic operations. The minor improvement in cell performance under dynamic mode might be associated with the relatively lower PO2 buildup as compared with that under galvanostatic operation. In addition, dynamic operation at high frequencies could effectively lower the extreme PO2 in the electrolyte, thus relieving stresses in the cells and alleviating cell degradation.
Degree
thesis:*- Grantor dc:publisher
- State University of New York at Buffalo
- Year dc:date.issued
- 2024
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Priest, Cameron; 0000-0003-2585-6844
- Contributors dc:contributor
-
- Wu, Gang
- Chemical and Biological Engineering
Subjects
dc:subject × 2Rights
dc:rights- Statement dc:rights
-
- Copyright retained by author. Users of works found in University at Buffalo Institutional Repository (UBIR) are responsible for identifying and contacting the copyright owner for permission to reuse. University at Buffalo Libraries do not manage rights for copyright-protected works and cannot assist with permissions.
- Language dc:language
- eng
Identifiers
dc:identifier.*- Handle dc:identifier
- http://hdl.handle.net/10477/90001