State University of New York at Buffalo
Studying the Energy Performance of Double-Skin Facade Configurations for Low-Rise Residential Buildings in Buffalo, New York
Abstract
dc:description.abstractThis study utilizes simulations to evaluate the energy performance of a multi-family house in Buffalo, New York. The house represents a residential typology in Buffalo called the “double”: a two-unit housing type featuring one family living on the first floor and another on the second floor beneath a steep gable roof. This study aims to provide an analysis of feasible DSF configurations that optimize indoor temperature control and energy performance for real-world applications. The primary focus of this research is to investigate the suitability of retrofitting buildings with double-skin façades (DSFs) under constraints such narrow property line by examining varying window opening percentages and cavity thicknesses. This research addressed the following questions: 1. What are the key design parameters to optimize DSFs in Buffalo, New York? 2. How do cavity depth and openings in a DSF impact the temperature of the DSF? The key performance metrics included two sets. The first set consisted of the annual heating and cooling load of the current house condition, modeled as a baseline, as well as an enhanced building with a DSF. The second data set included the zone air temperature of the DSF with different thicknesses and opening sizes. This allowed for a comparative analysis of different DSF design alternatives to find an optimized solution. A sensitivity analysis analyzed how small variations of opening and cavity depth in the model affect the output through twelve different configurations. For each DSF configuration, hourly zone temperatures were recorded. From this data, days with the highest and lowest temperatures—representing worst-case scenarios—were selected for further analysis. These days were drawn from December, January, and February for winter, and June, July, and August for summer. Additionally, the specific hours of 9:00 a.m., 12:00 p.m., 3:00 p.m., and 6:00 p.m. were analyzed on each selected day. Results indicate that a 15cm cavity depth with a 10% opening provides optimal thermal performance in winter by achieving higher midday temperatures, while the 0% opening configuration retains the most heat during summer, underscoring the significance of ventilation for managing heat gain. Findings from this research have implications for sustainable renovation practices in Buffalo’s residential sector, promoting DSFs as a possible alternative to conventional renovation techniques.
Degree
thesis:*- Grantor dc:publisher
- State University of New York at Buffalo
- Year dc:date.issued
- 2025
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Koushan, Sara
- Contributors dc:contributor
-
- Rajkovich, Nicholas
- Architecture
Subjects
dc:subject × 1Rights
dc:rights- Statement dc:rights
-
- Copyright retained by author. Users of works found in University at Buffalo Institutional Repository (UBIR) are responsible for identifying and contacting the copyright owner for permission to reuse. University at Buffalo Libraries do not manage rights for copyright-protected works and cannot assist with permissions.
- Language dc:language
- eng
Identifiers
dc:identifier.*- Handle dc:identifier
- http://hdl.handle.net/10477/90055