Back to search

State University of New York at Buffalo

Dimensional Changes in Invisalign Attachments During Treatment by Attachment Type and Complexity of Tooth Movement

Abstract

dc:description.abstract

Dimensional changes in Invisalign attachments during treatment by attachment type and complexity of tooth movement. Introduction: The efficacy of tooth movements with clear aligner therapy has been a heavily studied topic in the recent decades. To aid in tooth movement, composite attachments are placed on teeth for both anchorage and force delivery purposes. The wear of both attachments and the tray material might have an effect on the forces delivered to the teeth during tooth movement. The type of tooth movement occurring might also alter treatment efficacy. This study aims to highlight the differences in attachment wear by tooth movement type and attachment design to further add to the factors contributing to clear aligner success. This study is new in that the association between attachment wear and tooth movement type has not been evaluated to our knowledge. By knowing this association, clinicians may be able to decipher which attachments to replace sooner than others based on tooth movement type. Objectives: The objectives of this study were to assess the dimensional changes in Invisalign attachments by tooth movement type and attachment type. Methods: This is a retrospective comparative study of wear on the attachments of 45 patients treated with clear aligners (Invisalign, Align Technology, San Jose, CA) using digital superimposition software (Medit Link v 3.3.2; Medit, Seoul, Republic of Korea). The attachments that met inclusion criteria were split into two groups, those on teeth undergoing challenging tooth movements, and those on teeth undergoing relatively predictable tooth movements. Within these two groups, two subgroups were also analyzed: optimized and conventional attachments. By superimposing the stereolithography (STL) files at two timepoints, refinement scan 1 (T1) and refinement scan 2 (T2), the wear of each attachment was able to be studied via Medit Link software. The calculated root mean square (RMS) values were compared between the groups and subgroups. A visual analysis of the superimposition color maps was also utilized to interpret the direction of tooth movement occurring in relation to the surface area changes observed…

Degree

thesis:*
Grantor dc:publisher
State University of New York at Buffalo
Year dc:date.issued
2025

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Jarkowski, Ashley
Contributors dc:contributor
  • Warunek, Stephen
  • Orthodontics

Subjects

dc:subject × 4

Rights

dc:rights
Statement dc:rights
  • Copyright retained by author. Users of works found in University at Buffalo Institutional Repository (UBIR) are responsible for identifying and contacting the copyright owner for permission to reuse. University at Buffalo Libraries do not manage rights for copyright-protected works and cannot assist with permissions.
Language dc:language
eng

Identifiers

dc:identifier.*
Handle dc:identifier
http://hdl.handle.net/10477/90284

Chain of custody

source
Harvested from
Buffalo
Base URL
ubir.buffalo.edu/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Jarkowski, Ashley. Dimensional Changes in Invisalign Attachments During Treatment by Attachment Type and Complexity of Tooth Movement. State University of New York at Buffalo, 2025. http://hdl.handle.net/10477/90284