State University of New York at Buffalo
Methods for User and Procedural Bias Reduction in Quantitative Angiography of Intracranial Aneurysms
Abstract
dc:description.abstractIntracranial aneurysm occlusion assessment has long relied on digital subtraction angiography (DSA), but inherent biases and inconsistencies limit its reliability. One of the biggest challenges lies in the contrast injection variability caused by hand injection methods. The hand injection variability introduces unpredictable variations in contrast delivery, distorting time density curves (TDCs) and reducing reliability of quantitative angiographic analysis. To address this issue, a novel approach using Singular Value Decomposition (SVD) based deconvolution method was introduced, effectively isolating the aneurysm’s impulse response from injection-dependent variables. We standardize the arterial input function (AIF) by convolving impulse response function (IRF) with it, ensuring that the hemodynamic parameters reflect true physiological conditions rather than the artifacts introduced by the imaging process. However, even with standardized injection profiles, another major issue persists which is projection foreshortening bias. Since 2D angiography inherently compresses 3D vascular structures into a flattened projection, quantitative angiography biomarkers can be misrepresented. This challenge was tackled through Path-Length Correction (PLC), a technique that co-registers angiographic images with 3D vessel reconstructions to correct for variations in X-ray path length. When combined PLC with SVD-based deconvolution, this approach significantly improved the accuracy of angiographic biomarkers, allowing for more reliable intraoperative assessments. In addition to improving imaging techniques, the next frontier in aneurysm management is leveraging artificial intelligence (AI) models to predict treatment outcomes. While deep learning has shown promise in predicting occlusion after flow diverter placement, inconsistencies in angiographic parameters have made predictions unreliable. By incorporating SVD corrected hemodynamic parameter metrics into a neural network model, occlusion prediction accuracy increased substantially. More importantly, the addition of explainable AI (XAI) techniques, such as Local Interpretable-Agnostic Explanations (LIME), provided clinicians with insights into which imaging features influenced model decisions, bridging the gap between AI and clinical intuition. Together, these advancements form a comprehensive framework for bias-corrected, AI-enhanced quantitative angiography (QA), ensuring that aneurysm rupture assessment, treatment planning, and outcome prediction are more precise, reliable, and clinically interpretable.
Degree
thesis:*- Grantor dc:publisher
- State University of New York at Buffalo
- Year dc:date.issued
- 2025
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Mondal, Parmita
- Contributors dc:contributor
-
- Ionita, Ciprian
- Biomedical Engineering
Subjects
dc:subject × 1Rights
dc:rights- Statement dc:rights
-
- Copyright retained by author. Users of works found in University at Buffalo Institutional Repository (UBIR) are responsible for identifying and contacting the copyright owner for permission to reuse. University at Buffalo Libraries do not manage rights for copyright-protected works and cannot assist with permissions.
- Language dc:language
- eng
Identifiers
dc:identifier.*- Handle dc:identifier
- http://hdl.handle.net/10477/90298