Back to search

State University of New York at Buffalo

Advanced RF Hardware Solutions for Improved Imaging Performance and Safety in Ultra-High and Very-Low-Field MRI

Abstract

dc:description.abstract

Magnetic resonance imaging (MRI) continues to evolve across a wide range of field strengths, from ultra-high-field (7T) to very-low-field (70 mT) systems. Despite their clinical potential, each regime presents unique challenges in RF coil design, affecting imaging quality, patient safety, and system accessibility. This dissertation introduces a series of innovations in antenna structures, multi-channel array configurations, safety enhancement techniques, and material-based performance improvements to address these challenges and expand MRI’s diagnostic capabilities. At ultra-high fields, discretely dielectric-coated dipole (DDMC) antennas were developed to improve tuning stability, B1⁺ efficiency, and SAR control, offering a significant advancement over conventional designs. Complementary solenoidal dipole geometries further enhanced field uniformity for compact anatomical imaging. Extending these concepts to multi-channel arrays, systems such as a 15-channel DDMC dipole array and a 13-channel hybrid microstrip-birdcage array demonstrated improved B1⁺ coverage and SAR management across complex anatomical regions. Systematic evaluations of dipole types and array configurations provided new insights into optimizing SNR, field distribution, and inter-element coupling. At very-low-field, simulations revealed that superconducting materials substantially enhance coil SNR compared to room-temperature and low-temperature copper, particularly in surface coil designs. The integration of high-dielectric constant materials successfully mitigated electric fields and SAR in high-impedance coils, offering a pathway toward safer imaging. Finally, advanced catheter markers were designed for low-field interventional MRI, enabling robust, orientation-independent device visualization without disturbing background fields. Together, these advancements form a foundation for safer, higher-performance, and more accessible MRI systems, paving the way for future innovations in flexible coil arrays, dynamic SAR control, superconducting technologies, and portable MRI platforms.

Degree

thesis:*
Grantor dc:publisher
State University of New York at Buffalo
Year dc:date.issued
2025

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Bhosae, Aditya; 0000-0002-2796-1472
Contributors dc:contributor
  • Zhang, Xiaoliang
  • Biomedical Engineering

Subjects

dc:subject × 2

Rights

dc:rights
Statement dc:rights
  • Copyright retained by author. Users of works found in University at Buffalo Institutional Repository (UBIR) are responsible for identifying and contacting the copyright owner for permission to reuse. University at Buffalo Libraries do not manage rights for copyright-protected works and cannot assist with permissions.
Language dc:language
eng

Identifiers

dc:identifier.*
Handle dc:identifier
http://hdl.handle.net/10477/90300

Chain of custody

source
Harvested from
Buffalo
Base URL
ubir.buffalo.edu/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Bhosae, Aditya; 0000-0002-2796-1472. Advanced RF Hardware Solutions for Improved Imaging Performance and Safety in Ultra-High and Very-Low-Field MRI. State University of New York at Buffalo, 2025. http://hdl.handle.net/10477/90300