Back to search

State University of New York at Buffalo

Relationship between Implant Geometry and Primary Stability in Variant Bone Densities: An In Vitro Pilot Study

Abstract

dc:description.abstract

Background and Aim: The success of dental implants largely depends on achieving primary stability, especially in varied bone densities. Primary stability is influenced by factors such as implant geometry and bone density, which play crucial roles in osseointegration and the overall implant stability over time. While various implant designs have been developed, the optimal geometry for different bone densities remains unclear. This study aims to investigate the effect of four implant geometries Bone Level Tapered (BLT), Bone Level (BL), Tissue Level Standard Plus (SP), and Tissue Level Standard (S) on primary stability in medium-dense (D2) and soft (D4) bone densities. Methods: An in vitro pilot study was conducted using 96 osteotomies on porcine ribs as a bone model to replicate human bone conditions. Each implant geometry was placed in D2 and D4 bone densities, and primary stability was measured using resonance frequency analysis (RFA) through the Implant Stability Quotient (ISQ). Descriptive statistics and a two-way ANOVA were applied to assess the main effects of implant geometry and bone density on primary stability, as well as their interaction. Results: The dense bone (D2) group showed significantly higher ISQ values compared to the soft bone (D4) group across all implant geometries, indicating a strong effect of bone density on implant stability (p < .001). However, no statistically significant differences were found among the four implant geometries in terms of primary stability (p = .627). Additionally, there was no significant interaction effect between implant geometry and bone density (p = .506), suggesting that implant geometry did not influence stability differently in the two bone densities. Conclusions: Bone density was identified as a critical determinant of primary stability, with denser bone providing superior stability outcomes. The findings suggest that while implant geometry did not significantly impact stability in this controlled in vitro setup, bone quality assessment should be prioritized in clinical settings. Future research should examine long-term stability, including secondary stability and osseointegration, to validate these results in varied clinical scenarios.

Degree

thesis:*
Grantor dc:publisher
State University of New York at Buffalo
Year dc:date.issued
2025

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Alshayiqi, Mohammed; 0009-0003-9301-2392
Contributors dc:contributor
  • Li, Rui
  • Oral Biology

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • Copyright retained by author. Users of works found in University at Buffalo Institutional Repository (UBIR) are responsible for identifying and contacting the copyright owner for permission to reuse. University at Buffalo Libraries do not manage rights for copyright-protected works and cannot assist with permissions.
Language dc:language
eng

Identifiers

dc:identifier.*
Handle dc:identifier
http://hdl.handle.net/10477/90313

Chain of custody

source
Harvested from
Buffalo
Base URL
ubir.buffalo.edu/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Alshayiqi, Mohammed; 0009-0003-9301-2392. Relationship between Implant Geometry and Primary Stability in Variant Bone Densities: An In Vitro Pilot Study. State University of New York at Buffalo, 2025. http://hdl.handle.net/10477/90313