Back to search

State University of New York at Buffalo

Surface Coating of Orthodontic Elastomeric Chain with Quaternary Ammonium Silane: Retention of Coating and Effect on Tensile Strength

Abstract

dc:description.abstract

Objectives: This study aimed to quantitatively assess the coating of orthodontic elastomeric chains with quaternary ammonium silane (QAS), evaluate retention of the coating when chains were exposed to toothbrushing, and to determine if a QAS coating had any effect on tensile strength. Materials & Methods: A total of 264 clear colored open elastomeric chains were included in this in vitro study. The samples were separated into a control group (n=88), and two experimental groups. One experimental group was coated with HE4001 (Gelest, Morrisville, PA, USA) QAS at room temperature for 120 minutes (QAS-RT group, n=88) while the other experimental group was coated with the same QAS material under heated conditions of 99 degrees Celsius (QAS-99 group, n=88). Both groups were air dried at room temperature for 60 minutes. Chains were then exposed to simulation of toothbrushing for 1, 2 and 3 weeks. Retention of QAS coating was evaluated using bromophenol blue and spectrophotometry. Tensile strength testing was performed with a Universal Testing Machine (UTM). Descriptive statistics for both delta E and peak load were calculated by group and time. Linear models were constructed for both delta E and peak load to analyze the group and time differences. A robust linear model was constructed for delta E and p-values for the robust model and its respective post hoc contrasts were calculated by bootstrap with 10,000 resamples. All analysis used a significance level of 0.05 and were performed using RStudio (version 2024.12.0+467). Results: Significant differences in Delta E existed between all groups amongst all timepoints, except between QAS-RT and QAS-99 groups at T3. Within the QAS-RT group, significant differences in Delta E existed between T1-T3, and T2-T3 and within the QAS-99 group, significant differences in Delta E existed between T1-T3 and T2-T3. Significant differences in peak load existed within groups at various timepoints and between timepoints within groups. Conclusions: HE4001 can form a coating on polyurethane (PU) orthodontic elastomeric chains at both room temperature and under heated condition of 99 degrees Celsius. Both room temperature and heated treatments appear to perform similarly, with the HE4001 coating persisting for three weeks. There is significant loss of coating occurring within the first week of brushing. Tensile strength is not affected in a clinically relevant way. Continued antimicrobial tests must be completed to determine antimicrobial efficacy of 0.75% HE4001 coated chains.

Degree

thesis:*
Grantor dc:publisher
State University of New York at Buffalo
Year dc:date.issued
2025

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Simeone, Adrianna
Contributors dc:contributor
  • Warunek, Stephen
  • Orthodontics

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • Copyright retained by author. Users of works found in University at Buffalo Institutional Repository (UBIR) are responsible for identifying and contacting the copyright owner for permission to reuse. University at Buffalo Libraries do not manage rights for copyright-protected works and cannot assist with permissions.
Language dc:language
eng

Identifiers

dc:identifier.*
Handle dc:identifier
https://hdl.handle.net/10477/90524

Chain of custody

source
Harvested from
Buffalo
Base URL
ubir.buffalo.edu/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Simeone, Adrianna. Surface Coating of Orthodontic Elastomeric Chain with Quaternary Ammonium Silane: Retention of Coating and Effect on Tensile Strength. State University of New York at Buffalo, 2025. https://hdl.handle.net/10477/90524