Back to search

Brigham Young University

Predicted Strength and Ductility of Roof Truss Diaphragms with Tension-Only Rod Bracing and Hillside Washer Rod Connections

Abstract

dc:description.abstract

Metal buildings with roof truss diaphragms and tension-only rod bracing are a common structural system for single story industrial and commercial buildings. Despite the widespread use of metal building diaphragms in modern construction, there is limited knowledge on their strength and ductility under seismic loads. In this study, finite element models of diaphragm subassemblies and a full-size diaphragm were created to determine the strength and ductility of metal building diaphragms with tension-only rod bracing using hillside washer rod connections. Finite element models of two-tier diaphragm specimens that had been previously tested in the laboratory were created. Girders and purlins were modeled using elastic beam-column elements. Tension rods were modeled using elastic-perfectly plastic elements with a failure strain that was calibrated to match the subassembly test data. The tension rod anchorage connection was modeled using an elastic perfectly plastic gap material in series with an elastic material. The diaphragm subassembly model was subjected to monotonic and cyclic loading and the hysteresis results were used to determine the static subassembly strength and ductility. A finite element model of a full-size eight-tier roof truss diaphragm in a high-seismic location was created. The full-size model was subjected to monotonic and cyclic loading to determine static diaphragm strength and ductility. A parametric study was used to determine the effect of rod, purlin, girder, and friction parameters. The results of the parametric study indicate that the rod yield stress, rod size, rod connection stiffness and the friction force had a significant affect on the load-deformation response of the diaphragm, while other parameters had a negligible effect. From the subassembly model, predicted overstrength and ductility factors were found to range from 1.33 to 1.44 and 2.00 to 2.92 respectively. The calculated ductility factors were found to match the predicted ductility values. However, the overstrength factors varied from the predicted values. The full-size model was subjected to a ground motion record that was scaled to match the design response spectrum for the location. The results show that the dynamic diaphragm ductility capacity for this building was adequate to withstand the diaphragm ductility demand under the Maximum Considered Earthquake level ground motions for the ground motion examined.

Degree

thesis:*
Name thesis:degree_name
MS
Year dc:date
2024

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Brown, Emma Jean

Subjects

dc:subject × 7

Rights

Licence dc:rights.license
Language dc:language
english

Identifiers

dc:identifier.*
Repository record dc:identifier
https://scholarsarchive.byu.edu/etd/10768

Chain of custody

source
Harvested from
Brigham Young University
Base URL
scholarsarchive.byu.edu/do/oai/
Last updated
2026-11-27
Source record
OAI-PMH GetRecord
citation

Brown, Emma Jean. Predicted Strength and Ductility of Roof Truss Diaphragms with Tension-Only Rod Bracing and Hillside Washer Rod Connections. 2024. https://scholarsarchive.byu.edu/etd/10768