Back to search

Brigham Young University

An Active Quasi-Circulator IC and Technique for 1-255 MHz Resonance-Based Spectroscopic Impedance Plethysmography

Abstract

dc:description.abstract

Impedance measurement is a promising avenue for noninvasive glucosemonitoring. Specifically,resonance-basedimpedancemeasurements exhibit good correlation with glucose levels at excitations from tens of MHztoover 100 MHz. Additionally, plethysmographic impedance measurements are needed to separate arterial blood signals, which contain strongerglucose information, frominterstitialfluidsignals. Weanticipate that plethysmographic measurements across a range of frequencies— spectroscopic plethysmography—at excitations from tens to over 100 MHz could enable resonance-based monitoring with higher selectivity for arterial glucose than previous work. Afour-point impedance measurement circuit is designed, and its ability to measure constant and periodically time-varying impedance is demonstrated. This circuit presents high impedance to the device-undertest (DUT), which fails in the target range of tens to over 100 MHz due to the detrimental effects of parasitic capacitance. An active quasi-circulator (AQC) overcomes this challenge by instead presenting a controlled low impedance to the DUT. Thus, an impedance measurement technique utilizing the AQC is proposed. An initial version of the integrated circuit (IC) is fabricated and measured to demonstrate the proposed technique. Incorporating the AQC measurement technique, along with a proposed multirate filtering method which overcomes the challenge of impractically-high-Q filtering in post processing, a culminating version of the IC is presented. This IC is designed for the target application of resonance-based impedance measurements of human tissue at excitations from tens of MHz to over 100 MHz. The IC measures spectroscopic impedance plethysmography up to 255 MHz. In addition to the AQC, the IC features a source-follower DAC, excitation signal generation, and frequency downconversion. Electrical and human test results demonstrate, for the first time, spectroscopic plethysmography for resonance-based measurements, thus laying the groundwork for future studies of blood glucose–impedance correlation and other impedance measurements involving wearable arterial blood monitoring at these frequencies.

Degree

thesis:*
Name thesis:degree_name
PhD
Year dc:date
2025

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Poff, Sharisse

Subjects

dc:subject × 8

Rights

Licence dc:rights.license
Language dc:language
english

Identifiers

dc:identifier.*
Repository record dc:identifier
https://scholarsarchive.byu.edu/etd/11429

Chain of custody

source
Harvested from
Brigham Young University
Base URL
scholarsarchive.byu.edu/do/oai/
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Poff, Sharisse. An Active Quasi-Circulator IC and Technique for 1-255 MHz Resonance-Based Spectroscopic Impedance Plethysmography. 2025. https://scholarsarchive.byu.edu/etd/11429