Back to search

Graduate Studies

High Precision Measurements of 32S, 33S, and 34S Isotopic Composition by Multiple Collector Inductively Coupled Plasma Mass Spectrometry.

Abstract

dc:description.abstract

A reliable method was developed for sulfur isotopic composition measurements of sulfur solutions (10 ppm) using a 20 mL cyclonic quartz spray chamber and 50 μL/min (Glass Expansion Inc.) quartz nebulizer coupled to a high mass resolution Multiple Collector Inductively Coupled Plasma Mass Spectrometry (MC-ICP-MS). The repeatability of the method was tested which three reference materials (IAEA S-1, IAEA S-2, and IAEA S-3) and the ability to measure sulfur isotopic variations in hair sample was evaluated. The n(34S)/n(32S) and n(33S)/n(32S) isotope amount ratios were measured free from isobaric interferences (e.g. 16O2+ on 32S+ and 32S1H+ on 33S+) and corrected for instrumental mass bias adopting the standard-sample bracketing approach. The reproducibility of IAEA S-2 and IAEA S-3 is typically ± 0.19 ‰ and ±0.52 (2sd) for δ34S and δ33S, respectively and ± 0.30 ‰ and ± 0.53 ‰ (2sd) for δ34S and δ33S, respectively. Freedom from isobaric interferences was verified by plotting δ34S vs. δ33S. Cleanliness of the spray chamber was found to be extremely important to achieve reliable data. A microwave digestion method was developed to analyze sulfur in hair samples. The reproducibility of hair samples was typically ± 0.45 ‰ and ± 0.75 ‰ (2sd) for δ34S and δ33S values, respectively. Achieving a reliable method for δ34S and δ33S measurements will enable now a high precision measurement of sulfur isotopic composition.

Degree

thesis:*
Name thesis:degree_name
Master of Science (MSc)
Discipline thesis:degree_discipline
Physics and Astronomy
Grantor dc:publisher.institution
Graduate Studies
Year dc:date.issued
2014

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Alfayfi, Yahya
Advisor dc:contributor.advisor
  • Wieser, Michael

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission.
Language dc:language.iso
eng

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
University of Calgary
Base URL
ucalgary.scholaris.ca/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Alfayfi, Yahya. High Precision Measurements of 32S, 33S, and 34S Isotopic Composition by Multiple Collector Inductively Coupled Plasma Mass Spectrometry.. Graduate Studies, 2014. http://hdl.handle.net/11023/1542