Back to search

Graduate Studies

Behaviour of Concrete Beam-Column Joints Reinforced with Steel or Glass Fibre-Reinforced Polymer Double-Headed Studs for Seismic Resistance

Abstract

dc:description.abstract

Current code requirements for the design of beam-coumn joints shear reinforcement for earthquake resistance result in steel congestion, and consequently poor quality of the joint, construction difficulties and high cost. Based on previous research, steel studs with plain (non-deformed) stems and a head at each end can replace conventional closed hoops and cross ties for shear reinforcing the beam-column joints. Use of the headed studs in the joint results in reduction of the steel congestion, and hence, easier assemblage of the reinforcing cage and improved joint performance. The present research investigates experimentally the use of steel double-headed studs with deformed stems and Glass Fibre-Reinforced Polymer (GFRP) double-headed bars in lieu of the steel double-headed studs with plain stems. The experimental program consists of constructing and testing nine full-scale beam-column joint specimens under quasi-static cyclic loading. The specimens represent exterior beam-column joints subassembly isolated at the points of contra-flexure in a multi-storey multi-bay moment resisting concrete frame. The test parameters include the material and type of double-headed studs and their amount in the in-plane and out-of- plane directions and the concrete strength. Envelopes of the load-displacement hysteresis loops, moment-lateral drift angle, load-ductility, storey shear-drift angle, and the joint shear strength-deformation are plotted and analyzed. The stiffness degradation, the strains in the joint reinforcement, the contribution of specimen elements (joint, beam, and column) to the drift angle, and the energy dissipation capacity of the specimens are presented and discussed. Performance of the tested specimens is checked against the requirements and acceptance criteria of the ACI 374.1-05, ACI 252R-02 and CSA A23.3-04. The use of steel deformed studs or GFRP headed bars proved to be an acceptable replacement of closed hoops and cross-ties as shear reinforcement of beam-column joints. All of the tested specimens exhibited acceptable behavior satisfying the code requirements. Some specimens demonstrated better behavior in comparison with the specimen designed and reinforced according to the code provisions.

Degree

thesis:*
Name thesis:degree_name
Master of Science (MSc)
Discipline thesis:degree_discipline
Civil Engineering
Grantor dc:publisher.institution
Graduate Studies
Year dc:date.issued
2013

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Mojarrad Bahreh, Vahid
Advisor dc:contributor.advisor
  • El-Badry, Mamdouh

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission.
Language dc:language.iso
eng

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
University of Calgary
Base URL
ucalgary.scholaris.ca/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Mojarrad Bahreh, Vahid. Behaviour of Concrete Beam-Column Joints Reinforced with Steel or Glass Fibre-Reinforced Polymer Double-Headed Studs for Seismic Resistance. Graduate Studies, 2013. http://hdl.handle.net/11023/732