Back to search

Science

Optimising Ion Transport in a Thermal Ionisation Mass Spectrometer and Plasma Ion Source Using Monte Carlo Simulations

Abstract

dc:description.abstract

The controlled collimation of ion beams is of paramount importance in particle accelerators, high energy beamlines, and detector systems, as it determines the functionality, sensitivity and resolution of the instruments. In this thesis the ion source of a thermal ionization mass spectrometer (TIMS), comprised of a heated filament followed by a series of ion optical lenses, was modelled and Monte Carlo simulations were performed using SIMION. The potentials of three of the electrostatic lenses were optimized, in order to maximize the illuminated area of the exit slit. The optimization method employed achieved up to a 44 % increase in experimental signal intensity when compared to the existing manufacturer-provided lens tuning algorithm. 3D plots were effective in visualizing whether this new voltage configuration leads to a solution which lies in a local or global optimum, showing that the previous tuning technique was rarely successful in achieving the global optimum. This modelling and optimization approach was then used to aid the commissioning of a plasma ion source at the TITAN experiment at TRIUMF. The Plasma Ion Source (PIS), comprised of a heated filament followed by an anode, Einzel lens and X-Y correction steerers, was modelled and Monte Carlo simulations were performed. Optimising the voltage configurations in these simulations has proved successful in the commissioning of the PIS at the TITAN experiment in thermal mode, where ions from the source have been characterised using the time-of-flight method. The PIS will be able to deliver important calibration beams to TITAN’s experiments and will also enable off-line, high precision isotope composition measurements with the Multiple-Reflection Time-Of-Flight Mass Spectrometer (MR-TOF MS).

Degree

thesis:*
Name thesis:degree_name
Master of Science (MSc)
Discipline thesis:degree_discipline
Physics & Astronomy
Grantor dc:publisher.institution
Science
Year dc:date.issued
2019

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Flowerdew, Jake Anthony Darri
Advisors dc:contributor.advisor
  • Thompson, Robert Ian
  • Wieser, Michael E.
Committee members dc:contributor.committeemember
  • Jackel, Brian J.
  • Kwiatkowski, Anna A.
  • Friesen, Timothy P.

Subjects

dc:subject × 8

Rights

dc:rights
Statement dc:rights
  • University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission.
Language dc:language.iso
eng

Identifiers

dc:identifier.*
Dc Identifier Citation
Flowerdew, J. A. D. (2019). Optimising Ion Transport in a Thermal Ionisation Mass Spectrometer and Plasma Ion Source Using Monte Carlo Simulations (Master's thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca.

Chain of custody

source
Harvested from
University of Calgary
Base URL
ucalgary.scholaris.ca/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Flowerdew, Jake Anthony Darri. Optimising Ion Transport in a Thermal Ionisation Mass Spectrometer and Plasma Ion Source Using Monte Carlo Simulations. Science, 2019. http://hdl.handle.net/1880/111049