Back to search

Schulich School of Engineering

Flat Arch Masonry Retaining Wall

Abstract

dc:description.abstract

The inherent strength and durability of masonry arches is eminent through many historical structures still existing to this day. Amidst a wide range of retaining wall types and applications available, the concept of utilizing masonry arches as earth retaining structures is surprisingly unprecedented in the recent past. In this research, a novel masonry low-rise arch retaining wall is introduced. An experimental programme was implemented to explore the feasibility of the proposed earth retaining system, where a full-scale, concrete block arch wall was constructed between two rigid abutments and backfilled with soil. Surcharge loading was also applied to the backfill soil to explore the stability of the wall under additional dead loads. The concept is that the blockwork wall will resist the lateral pressure through arch action, avoiding “snap-through” of the wall. The response of the wall to the soil pressure, compaction and surcharge loading was monitored by observing deflections and strains in the wall. Furthermore, one half of the wall was fully grouted, while the other half was left hollow to compare the behaviour of the grouted and un-grouted masonry. Retaining walls are typically constructed using concrete, steel, masonry or timber. The use of concrete blocks in this instance was desirable due to its strength, ease of construction, cost effectiveness and aesthetic appearance. This makes such a wall ideal for low-rise retention, opening a new market in which masonry can compete. From the results of the experimental study, the efficacy of the proposed masonry arch retaining wall was substantiated with deflections less than 1.3% of the least dimension of the wall, compressive stresses well within the elastic range of masonry and no cracks observed in the visible region of the wall.

Degree

thesis:*
Name thesis:degree_name
Master of Science (MSc)
Discipline thesis:degree_discipline
Engineering – Civil
Grantor dc:publisher.institution
Schulich School of Engineering
Year dc:date.issued
2020

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Kurukulasuriya, Maithree Chiranthya
Advisors dc:contributor.advisor
  • Shrive, Nigel
  • Wong, Ron Chik Kwong
Committee members dc:contributor.committeemember
  • Dann, Markus R.
  • Federico, Salvatore

Subjects

dc:subject × 4

Rights

dc:rights
Statement dc:rights
  • University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission.
Language dc:language.iso
eng

Identifiers

dc:identifier.*
Dc Identifier Citation
Kurukulasuriya, M. C. (2020). Flat Arch Masonry Retaining Wall (Master's thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca.

Chain of custody

source
Harvested from
University of Calgary
Base URL
ucalgary.scholaris.ca/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Kurukulasuriya, Maithree Chiranthya. Flat Arch Masonry Retaining Wall. Schulich School of Engineering, 2020. http://hdl.handle.net/1880/112423