Back to search

Schulich School of Engineering

Removal of Dissolved Nitrogen Gas Using Mixed Liquor Vacuum Degassing in Biological Nutrient Removal Wastewater Treatment Facilities

Abstract

dc:description.abstract

The City of Calgary (The City) recently implemented a mixed liquor vacuum degassing (MLVD) system at Bonnybrook Wastewater Treatment Plant (WWTP) that uses rapid bubble desorption to lower the dissolved gas concentration in the mixed liquor, allowing for denitrification in the secondary clarifiers to occur while delaying microbubble formation. Total dissolved gas pressure (TDGP) sensors were constructed and deployed at site for a four-month test campaign to monitor TDGP in the wastewater before and after degasification. The MLVD system typically reduced the TDGP by 16 percent but the technology performance was inconsistent with the reduction in TDGP ranging from 10 to 26 percent. Vacuum pump off gas samples were analyzed to determine that nitrogen accounted for over 90 percent of the gas pressure reduction. As a result, the available capacity (in terms of concentration) for nitrogen to dissolve into solution prior to forming microbubbles in the secondary settling tanks (SSTs) (5 m deep tank with a 1 m deep sludge blanket) increased by 2 to 5 mg/L depending on MLVD performance (non-degassed mixed liquor available capacity of 7.4 mg/L increased to 9.5 to 12.5 mg/L after degasification). With inconsistent MLVD performance, an operational review was completed suggesting vacuum pump design improvements and operational optimization is required. Overall, the research provides an understanding and means to monitoring dissolved gas, specifically nitrogen, in biological nutrient removal facilities. Monitoring such parameters will become increasingly important as more stringent effluent requirements are enforced, wastewater becomes more concentrated through water conservation efforts, and processes are intensified within existing tankage.

Degree

thesis:*
Name thesis:degree_name
Master of Science (MSc)
Discipline thesis:degree_discipline
Engineering – Civil
Grantor dc:publisher.institution
Schulich School of Engineering
Year dc:date.issued
2022

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Hunter, Michael
Advisor dc:contributor.advisor
  • Chu, Angus
Committee members dc:contributor.committeemember
  • He, Jianxun
  • Pishgar, Roya
  • Huang, Wendy

Subjects

dc:subject × 8

Rights

dc:rights
Statement dc:rights
  • University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission.
Language dc:language.iso
eng

Identifiers

dc:identifier.*
Dc Identifier Citation
Hunter, M. (2022). Removal of Dissolved Nitrogen Gas Using Mixed Liquor Vacuum Degassing in Biological Nutrient Removal Wastewater Treatment Facilities (Master's thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca.

Chain of custody

source
Harvested from
University of Calgary
Base URL
ucalgary.scholaris.ca/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Hunter, Michael. Removal of Dissolved Nitrogen Gas Using Mixed Liquor Vacuum Degassing in Biological Nutrient Removal Wastewater Treatment Facilities. Schulich School of Engineering, 2022. http://hdl.handle.net/1880/114859