Back to search

Schulich School of Engineering

Methodological Analysis of an Improved Gluten Quantitation Aptamer-based Biosensor

Abstract

dc:description.abstract

Fluorescence resonance energy transfer based aptamer are currently being studied in many research groups due to their potential contribution as an alternative gluten standard for gluten- quantitation. The current gold standard withholds critical limitations due to the nature of the system, hence this aptamer-based sensor (or aptasensor for short) application represents one of the alternatives; yet, drawbacks such as low signal-to-noise ratio and reliability are in the scope of research groups aiming to overcome them. In this study, multiple variations of the protocol are assessed based on correctly classifying food samples as their actual concentration of gluten, this is coined as the accuracy of the biosensor. The study also aims to overcome the current limitation of the gold standard in fermented samples by including soy sauce and malt vinegar in the tests. And different additives aiming to help overcoming the limitation were implemented into the protocol and assessed. This approach allowed the biosensor to classify the products with 98.28% of accuracy, and 0% of error in classifying gluten-rich products (false-negatives) within the first 3 days of bioassay preparation; yet, this bioassay needs to be studied further as only 18 different off-the-shelf products were tested (over 800 tests in total). Additionally, after the first week, false-negatives increased to around 5% and remained that way until the end of the first month. The cause of this relies mostly on the decomposition of the conjugate reduced graphene oxide and polyethylene glycol that are implemented in the system. This implies that further research aiming solely at additives or alternative reagents that increase the lifespan or stability of the conjugate would augment the overall performance.

Degree

thesis:*
Name thesis:degree_name
Master of Science (MSc)
Discipline thesis:degree_discipline
Engineering – Electrical & Computer
Grantor dc:publisher.institution
Schulich School of Engineering
Year dc:date.issued
2022

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Kuri Martinez, Juan Carlos
Advisors dc:contributor.advisor
  • Yadid-Pecht, Orly
  • Turner, Raymond J.
Committee members dc:contributor.committeemember
  • Murari, Kartikeya
  • Birss, Viola Ingrid

Subjects

dc:subject × 8

Rights

dc:rights
Statement dc:rights
  • University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission.
Language dc:language.iso
eng

Identifiers

dc:identifier.*
Dc Identifier Citation
Kuri Martinez, J. C. (2022). Methodological analysis of an improved gluten quantitation aptamer-based biosensor (Master's thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca.

Chain of custody

source
Harvested from
University of Calgary
Base URL
ucalgary.scholaris.ca/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Kuri Martinez, Juan Carlos. Methodological Analysis of an Improved Gluten Quantitation Aptamer-based Biosensor. Schulich School of Engineering, 2022. http://hdl.handle.net/1880/115284