Schulich School of Engineering
Quantification of Fugitive Area Emissions Using Optical Remote Sensing Computed Tomography and Inverse Dispersion Modeling Techniques
Abstract
dc:description.abstractReducing methane (CH4) emissions from anthropogenic activities is critical to climate change mitigation efforts. But there is still considerable uncertainty over the amount of fugitive CH4 emissions due to large-scale area sources and heterogeneous emission distributions. To improve the accuracy, a new hybrid method with high spatial and temporal resolutions is developed by combining optical remote sensing (ORS), computed tomography (CT), and inverse-dispersion modeling techniques. A multi-path scanning system is also developed using the horizontal radial plume mapping (HRPM) path geometry. The method adapts a Lagrangian stochastic (LS) dispersion model into CT reconstruction to derive emission distribution. Forward and backward LS models are developed and comprehensively compared to increase the model accuracy by supporting time-varying inputs. Controlled-release experiments of CH4 show this approach improves the accuracy by 5%-20% compared to the method using constant inputs. To address the challenges posed by limited path number and uneven sampling of HRPM path configuration, it uses a smooth algorithm of low third derivative (LTD) coupled with high-resolution grid division to improve the performance. By adapting the interpolation technique into CT reconstruction, a new minimal curvature (MC) algorithm based on the variational interpolation technique is formulated, showing significant improvement to the non-negative least squares (NNLS) algorithm and requiring approximately 65% computation time of LTD. To reconstruct realistic plume shape, a new Gaussian dispersion transformation algorithm is developed by introducing dispersion-related information. Numerical studies and controlled-release experiments show approximately 16% better performance on nearness than the NNLS and LTD algorithms. The combined method was evaluated through two controlled-release experiments of CH4, showing relative errors of only 2% and 3% compared to 5% - 175% for the single-path method. Field measurements of landfill CH4 emissions were first conducted in a scale-up site. Hotspots are successfully identified. The relative emission rate is 12.5%. Then, a test in a landfill biowindow area shows that more hotspots are successfully identified than the flux chamber method. The average emission rate over the site is 0.84 mg.m-2.s-1. The outcome of this research would bring broad application of the ORS-CT and inverse-dispersion techniques to other gases and sources.
Degree
thesis:*- Name thesis:degree_name
- Doctor of Philosophy (PhD)
- Discipline thesis:degree_discipline
- Engineering – Mechanical & Manufacturing
- Grantor dc:publisher.institution
- Schulich School of Engineering
- Year dc:date.issued
- 2022
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Li, Sheng
- Advisor dc:contributor.advisor
-
- Du, Ke
- Committee members dc:contributor.committeemember
-
- Johansen, Craig
- Kim, Seonghwan
- Ramirez-Serrano, Alejandro
- Hugenholtz, Christopher
- Hashisho, Zaher
Subjects
dc:subject × 5Rights
dc:rights- Statement dc:rights
-
- University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission.
- Language dc:language.iso
- eng
Identifiers
dc:identifier.*- Dc Identifier Citation
- Li, Sheng (2022). Quantification of fugitive area emissions using optical remote sensing computed tomography and inverse dispersion modeling techniques (Doctoral thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca.