Science
Total Organic Halogen: Method Development and Quantification in an Electrochemical Advanced Oxidation System for Water Disinfection
Abstract
dc:description.abstractThe work of this thesis comprehensively quantifies halogenated disinfection by-products (DBPs) and halogenated emerging contaminants in drinking water and wastewater. DBPs are formed during water disinfection when natural organic matter reacts with the disinfectant. DBPs have been shown to display genotoxic, cytotoxic, and potentially carcinogenic properties to humans. Recently, electrochemical treatment has become of interest given its ability to provide simultaneous disinfection and oxidation of chemical compounds. Chapter 2 includes an analytical method that quantifies total organic halogen (TOX) in water. The TOX method provides a comprehensive and non-target evaluation of waters containing DBPs and halogenated emerging contaminants and is quantified as total organic fluorine (TOF), chlorine (TOCl bromine (TOBr), and iodine (TOI). Twelve emerging contaminants were spiked into ultrapure water and wastewater with recoveries between 19-107. The method was applied to four wastewaters prior to disinfection across 2 cities in Alberta, Canada. TOF ranged from 4.9 - 10.5 µg/L, TOCl ranged from 67.5 - 80.0 µg/L, TOBr ranged from 5.0 – 9.0 µg/L, and TOI was only detected in two samples at 1.8 and 6.1 µg/L. An emerging contaminants target analysis for 196 compounds was able to identify 1.5% of TOX in a wastewater sample.In Chapter 3, the formation of DBPs produced by BioLargo Water’s AOS was assessed. The reactor was evaluated by treating pure water, river water, and secondary wastewater effluent with the AOS. Target DBP analysis was used that included 25 unregulated DBP. Ultrapure water disinfection only quantified triiodomethane at a maximum concentration of 0.90 ± 0.05 µg/L. River water results show that TOI increase from 1.26 ± 0.26 µg/L before disinfection (t=0) to a maximum of 3.50 ±1.11 µg/L. Secondary wastewater effluent disinfection results show that TOI increased from 1.75 ± 0.25 µg/L (t=0) to a maximum concentration of 35.29 ± 0.31 µg/L. Iodide and iodate were the main iodinated species exiting the AOS with an iodine recovery of 94-101%. The results from this study show that the AOS formed low levels of iodinated DBPs in treated water sources that are comparable to the levels found in disinfected drinking water and wastewater.
Degree
thesis:*- Name thesis:degree_name
- Master of Science (MSc)
- Discipline thesis:degree_discipline
- Chemistry
- Grantor
- Science
- Year dc:date.issued
- 2021
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Verwold, Chad M
- Advisor dc:contributor.advisor
-
- Kimura-Hara, Susana Y.
- Committee members dc:contributor.committeemember
-
- Thurbide, Kevin
- Roberts, Edward
Subjects
dc:subject × 5Rights
- Language dc:language.iso
- English
Identifiers
dc:identifier.*- Dc Identifier Citation
- Verwold, C. M. (2021). Total Organic Halogen: Method Development and Quantification in an Electrochemical Advanced Oxidation System for Water Disinfection (Master thesis). University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca .