Back to search

Schulich School of Engineering

Development and Validation of a Current-Based EEG System for Tangential Current Measurement

Abstract

dc:description.abstract

Voltage-based electroencephalography (vEEG) and magnetoencephalography (MEG) are among the state-of-the-art non-invasive methodologies to study the electrophysiology of the human brain. Both methodologies offer high temporal but limited spatial resolution. vEEG and MEG are sensitive to radially and tangentially oriented dipoles in the brain, respectively. This complementary information improves the achievable spatial resolution when used simultaneously in source localization applications (e.g., locating epilepsy foci). However, MEG is not as easily accessible as vEEG. The initial setup cost of an MEG system is in the order of millions of US dollars (USD), and the yearly operational cost can be hundreds of thousands of USD. Conversely, a high-end vEEG system can be acquired for tens of thousands of USD and require minimal maintenance. In some topologies, vEEG can measure from tangential dipoles, but suffers from fundamental limitations regarding signal strength. To address the technological need for a more accessible technology than MEG that can measure tangential dipoles in the brain, I developed a current-based EEG (cEEG) system. The cEEG has a front-end transimpedance amplifier to measure currents that are caused by tangential dipoles. A one-channel cEEG amplifier was conceptualized, designed, simulated, implemented, and characterized for validating the proposed current-based technology. The characterization met design goals set to reliably measure brain currents. Using phantom and simulation models, I found that cEEG is mostly influenced by tangential dipoles. Further, the cEEG was used to measure alpha waves during a resting, and steady-state visual evoked potentials paradigms to measure brain activity from ten healthy individuals. Statistical analysis of the experimental data showed that the cEEG could effectively measure brain activity. Towards the development of a multichannel system, a second cEEG was developed with a microcontroller for on-board digitization of the amplified and filtered signal. This implementation allows the cEEG to have isolated power supplies, which are required if multiple amplifiers were to be used. cEEG systems open up the possibility to understand brain activity from a different perspective in research and clinical applications.

Degree

thesis:*
Name thesis:degree_name
Doctor of Philosophy (PhD)
Discipline thesis:degree_discipline
Engineering – Biomedical
Grantor
Schulich School of Engineering
Year dc:date.issued
2021

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Comaduran Marquez, Daniel
Advisor dc:contributor.advisor
  • Murari, Kartikeya
Committee members dc:contributor.committeemember
  • Sotero-Diaz, Roberto C.
  • Federico, Paolo

Subjects

dc:subject × 7

Rights

Language dc:language.iso
English

Identifiers

dc:identifier.*
Dc Identifier Citation
Comaduran Marquez, D. (2021). Development and Validation of a Current-Based EEG System for Tangential Current Measurement (Doctoral thesis). University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca .

Chain of custody

source
Harvested from
University of Calgary
Base URL
ucalgary.scholaris.ca/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Comaduran Marquez, Daniel. Development and Validation of a Current-Based EEG System for Tangential Current Measurement. Schulich School of Engineering, 2021. http://hdl.handle.net/1880/116316