Graduate Studies
Thermodynamic Investigation of an Integrated Air-Based Solar Collector-Air Source Heat Pump System (ASC-ASHP) for Domestic Hot Water and Residential Space Heating in Cold Climates
Abstract
dc:description.abstractReducing building-related CO2 emissions require decreasing energy consumption and/or adopting cleaner, more efficient technologies. Air source heat pumps (ASHPs) are becoming famous for heating applications, particularly in moderate climatic conditions. However, in colder climates, their efficiency and capacity are reduced significantly and require high auxiliary heating loads. As such, coupling ASHPs with solar energy and energy storage systems is receiving considerable interest. This study investigates the performance of a solar air collector (SAC) integrated ASHP for domestic hot water (DHW) production and residential space heating in an extremely cold climate. The mathematical model of the entire system, including an SAC, ASHP and the thermal energy storage (TES) tank, was developed and implemented in a transient system simulation tool (TRNSYS). The building model was developed in TRNBuild and coupled with the heating system in the TRNSYS simulation studio. The impact of collector orientation, with tilt angles between 30 and 70o, collector surface areas (8-16 m2) and mass flow rates (0.25-1 kg/s), which are considered suitable for a 2.5-ton heat pump, were systematically examined. Additionally, a control strategy based on outdoor air temperature ranging from -10°C to -25°C and solar radiation intensity ranging from 0 to 300 W/m² was evaluated. Furthermore, a heat recovery mechanism is employed to recirculate air within the SAC based on the heat pump’s evaporator outlet temperature. The heating model is also extended to residential space heating via a radiant floor system for an 852-square-foot house and evaluated for different sizes of collectors and control strategies same as the application of DHW. For DHW, the results indicate that the optimal tilt angle for maximizing annual useful energy gain is 51°, corresponding to Calgary’s latitude. Moreover, the integration of an SAC enhances the annual average coefficient of performance (COP) of the ASHP by 16% for DHW. Furthermore, with the implementation of optimized control strategies and a recirculation mechanism, this improvement can reach up to 24%. For space heating, incorporating a 40 m² SAC increases the ASHP’s COP by approximately 7%. An economic and environmental analysis further confirms the viability and sustainability of the integrated SAC-ASHP heating model.
Degree
thesis:*- Name thesis:degree_name
- Master of Science (MSc)
- Discipline thesis:degree_discipline
- Engineering – Mechanical & Manufacturing
- Grantor dc:publisher.institution
- Graduate Studies
- Year dc:date.issued
- 2025
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Bhadra, Sheel
- Advisor dc:contributor.advisor
-
- Mwesigye, Aggrey
- Committee members dc:contributor.committeemember
-
- Li, Simon
- Assefa, Getachew
Subjects
dc:subject × 7Rights
dc:rights- Statement dc:rights
-
- University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission.
- Language dc:language.iso
- en
Identifiers
dc:identifier.*- Dc Identifier Citation
- Bhadra, S. (2025). Thermodynamic investigation of an integrated air-based solar collector-air source heat pump system (ASC-ASHP) for domestic hot water and residential space heating in cold climates (Master's thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca.