Back to search

Schulich School of Engineering

Near Field Microwave Tomography for Hydration Assessment

Abstract

dc:description.abstract

Water is a critical nutrient in the body required for many physiological processes. Dehydration of as little as 2% can negatively impact physical and mental performance. In certain at-risk populations such as the elderly, maintaining proper hydration can prove difficult, compounding existing conditions. The lack of a gold standard method of dehydration monitoring motivates the development of new techniques. The dielectric properties of human tissue in the microwave frequency range are closely related to their water content, making microwave imaging and sensing techniques a promising modality for monitoring changes in hydration. Microwave tomography is an imaging technique that solves the inverse scattering problem to generate quantitative images of an object’s dielectric properties. The goal of this thesis is to design, implement, and validate a microwave tomography system for hydration assessment. Using ground beef as a model of human muscle tissue, an experiment in which ground beef samples were measured from baseline hydration to 7% dehydration showed a 5% decrease in permittivity and a 3–5% decrease in conductivity in the low GHz range. Additionally, a robust statistical model for analyzing dielectric measurements was presented. The use of subwavelength focused fields to linearize the inverse scattering problem was investigated, exploring the physical origins of the problem’s ill-posedness and nonlinearity. Next, a physics-informed regularization technique using electromagnetic power balance was introduced to improve image reconstruction in biomedical scenarios. An inexpensive PCB-based electrically small dipole antenna was then introduced for in-contact microwave tomography. By prioritizing robust antenna performance and compact form factor over efficiency, a high-performance in-contact antenna was designed. Finally, this antenna was integrated into a microwave tomography system. By using a parametric inversion based on segmented qualitative images of the forearm, the bulk dielectric properties were reliably estimated. The technique and system were validated in simulation, with simple forearm phantoms, and with a feasibility study of a volunteer undergoing exercise-induced dehydration.

Degree

thesis:*
Name thesis:degree_name
Doctor of Philosophy (PhD)
Discipline thesis:degree_discipline
Engineering – Electrical & Computer
Grantor
Schulich School of Engineering
Year dc:date.issued
2026

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Besler, Brendon Chisholm Brian
Advisor dc:contributor.advisor
  • Fear, Elise Carolyn
Committee members dc:contributor.committeemember
  • Okoniewski, Michal
  • Lamoureux, Michael
  • Boyd, Steven
  • Gilmore, Colin

Subjects

dc:subject × 2

Rights

dc:rights
Statement dc:rights
  • Unless otherwise indicated, this material is protected by copyright and has been made available with authorization from the copyright owner. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission.
Language dc:language.iso
en

Identifiers

dc:identifier.*
Dc Identifier Citation
Besler, B. C. B. (2026). Near field microwave tomography for hydration assessment (Doctoral thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca.

Chain of custody

source
Harvested from
University of Calgary
Base URL
ucalgary.scholaris.ca/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Besler, Brendon Chisholm Brian. Near Field Microwave Tomography for Hydration Assessment. Schulich School of Engineering, 2026. https://hdl.handle.net/1880/124707