Back to search

Cal Poly

Design and Validation of a Wearable SmartSole for Continuous Detection of Abnormal Gait

Abstract

dc:description.abstract

Residual gait abnormalities are common following lower limb injury and/or stroke and can have several negative impacts on an individual’s life. Without continuous treatment and follow up, individuals can be prone to chronic pain as abnormal gait may lead to non-physiological loading of the musculoskeletal system. The current industry gold standard for diagnosing abnormal gait requires specialty equipment that is generally only available at designated gait facilities. Due to the inaccessibility and high cost associated with these facilities, a wearable SmartSole device to continuously detect abnormal gait was proposed. A previous iteration of the SmartSole was unable to properly detect abnormal gait and also experienced fracturing throughout the 3D printed body. In this present study, sensor placement and material selection were reconsidered to address these limitations. The objective of this study was to determine if a redesigned SmartSole could identify events of abnormal gait through validation and verification testing against the industry standard force plates. In total, 14 participants were selected for gait studies, 7 with pronounced gait abnormalities (e.g. limps), and 7 with physiological gait. Parameters of interest included stance time, gait cycle time, and the ratio of the force magnitudes recorded during heel strike and toe off. Results indicated that the SmartSole was effective at determining overall event timings within the gait cycle, as both stance and cycle time had strong, positive correlations (left stance: r = 0.761, right stance: r = 0.560, left cycle: r = 0.688) with the force plates, with the exception of right foot cycle time. The sole was not effective at measuring actual values of events during gait as there were weak correlations with the force plates. Furthermore, when comparing parameters of interest between the injured and non-injured sides for test participants with gait abnormalities, neither the SmartSole nor the force plates were able to detect significant differences. The inability of the sole to accurately collect force magnitudes or to detect abnormal gait leads to the conclusion that additional sensors may need to be implemented. Future iterations may consider placement of additional sensors to allow for a “fuller picture” and the inclusion of other types of sensors for improved, continuous tracking of gait abnormalities.

Degree

thesis:*
Name thesis:degree_name
MS in Biomedical Engineering
Discipline thesis:degree_discipline
Biomedical Engineering

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Wucherer, Karoline M
Contributors dc:contributor
  • Scott Hazelwood
  • Biomedical Engineering
  • College of Engineering

Subjects

dc:subject × 5

Identifiers

dc:identifier.*
Repository record dc:identifier
https://digitalcommons.calpoly.edu/theses/2773

Chain of custody

source
Harvested from
Cal Poly
Base URL
digitalcommons.calpoly.edu/do/oai/
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Wucherer, Karoline M. Design and Validation of a Wearable SmartSole for Continuous Detection of Abnormal Gait. https://digitalcommons.calpoly.edu/theses/2773