Back to search

Cal Poly

Evaluation of Antibiotic Testing Protocols for Biofilm-Forming Escherichia Coli in a Microfluidic Platform

Abstract

dc:description.abstract

Catheter-associated urinary tract infections remain an ongoing clinical problem due to biofilm persistence and antibiotic resistance. Standard antibiotic susceptibility testing cannot accurately reproduce flow conditions and the spatial complexity of the in vivoenvironment and is thus questionable in relevance to device-related infections. This study examines a microfluidic device designed to simulate physiologically relevant wall shear stress and antibiotic gradients in Escherichia coli biofilms. The polydimethylsiloxane-based system integrates a 16-well culture chamber with a gradient generator. Biofilm growth was observed using fluorescence microscopy of green fluorescent protein-labeled bacteria. Simulations performed using COMSOL Multiphysics software estimated the appropriate range of wall shear stress values (10⁻⁴-10⁻³ Pa) maintained by the device to match indwelling catheter conditions. The consistency analysis of the device indicated that the fabrication temperature had an impact on the retention of tubing and rate of delamination, and the best performance was achieved at 100 °C bonding. Experimental data suggested flow-dependent modulation in growth, spatial growth biases along the direction of seeding inlet, and non-uniform responses to ciprofloxacin gradients, potentially influenced by diffusion at low shear conditions, with small impact on fluorescence at high antibiotic concentrations. While ciprofloxacin exposure produced inconclusive inhibition patterns, the observed biofilm formation under defined flow conditions indicates that the current device design has potential to function as intended. Future improvements, such as vacuum-assisted bonding, enhanced tubing retention, and the use of alternative ciprofloxacin concentrations, may enable more reliable antibiotic susceptibility testing.

Degree

thesis:*
Name thesis:degree_name
MS in Biomedical Engineering

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Telander, Caleb R
Contributors dc:contributor
  • Ben Hawkins
  • Biomedical Engineering
  • College of Engineering

Subjects

dc:subject × 7

Identifiers

dc:identifier.*
Repository record dc:identifier
https://digitalcommons.calpoly.edu/theses/3030

Chain of custody

source
Harvested from
Cal Poly
Base URL
digitalcommons.calpoly.edu/do/oai/
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Telander, Caleb R. Evaluation of Antibiotic Testing Protocols for Biofilm-Forming Escherichia Coli in a Microfluidic Platform. https://digitalcommons.calpoly.edu/theses/3030