Back to search

Cal Poly

Muscle Impulse Transducer: Research, Pre-Pilot Experiments, and the Design of a Pilot Study for Quadriplegic Spinal Cord Injured Subjects for the Development of a Novel Device

Abstract

dc:description.abstract

Paralysis due to spinal cord injury is a challenging condition that affects millions of people around the world. The Muscle Impulse Transducer (MIT) is a novel, wearable device that can be used to improve grip strength in the hand by using functional muscle impulses as a trigger for stimulus delivery to weakened or paralyzed nerves, to induce contraction of a paralyzed or paretic muscle. The MIT is still in development, with proof of concept [1], and functional prototypes [2] achieved. In this thesis, research was conducted on the best methods for functional electrical stimulation, EMG data collection, and nerve stimulus delivery. Pre-pilot experiments were performed to collect data in healthy subjects on maximum EMG levels (mV) at different loading levels of the biceps, triceps, and forearm muscles, as well as stimulus threshold currents for device configuration. This pre-pilot work showed maximum EMG values (mV) and current threshold values (mA) in healthy subjects, and showed the variation in different muscles EMG with increased loading, as well as normal values for current threshold. The pre-pilot experiments also provided valuable qualitative information on changes to the data collection assembly for the Pilot study design. The research and pre-pilot experiments conducted contributed the information for the design of a Pilot study in the subjects of interest for the device. The Pilot study is designed to collect data from quadriplegic test subjects to inform decisions about the next generation of the MIT. The data to be collected in the Pilot study as designed are maximum EMG values (mV) during biceps curls completed at different loading levels, threshold and maximum current values (mA) with corresponding thumb contraction force values (N), thumb contraction force (N) for current delivered between threshold current and maximum values, and thumb contraction force (N) and duration (ms) during delivery of one to ten current pulses at threshold, median, and maximum current values. As designed, the Pilot study should provide ample information to determine the superior trigger muscle for the MIT, and the superior method for including step levels to the device function.

Degree

thesis:*
Name thesis:degree_name
MS in Biomedical Engineering
Discipline thesis:degree_discipline
Biomedical Engineering

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Oreglia, Marta
Contributors dc:contributor
  • Ben Hawkins
  • Biomedical Engineering
  • College of Engineering

Subjects

dc:subject × 2

Identifiers

dc:identifier.*
Repository record dc:identifier
https://digitalcommons.calpoly.edu/theses/3223

Chain of custody

source
Harvested from
Cal Poly
Base URL
digitalcommons.calpoly.edu/do/oai/
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Oreglia, Marta. Muscle Impulse Transducer: Research, Pre-Pilot Experiments, and the Design of a Pilot Study for Quadriplegic Spinal Cord Injured Subjects for the Development of a Novel Device. https://digitalcommons.calpoly.edu/theses/3223