Back to search
Department of Human Biology
Real-time motion and main magnetic field correction in MR spectroscopy using an EPI volumetric navigator
Abstract
dc:description.abstractIn population groups where subjects do not lie still during Magnetic Resonance Spectroscopy (MRS) scans, real-time volume of interest (VOI), frequency, and main magnetic field (B0) shim correction may be necessary. This work demonstrates firstly that head movement causes significant B0 disruption in both single voxel spectroscopy and spectroscopic imaging.
Degree
thesis:*- Grantor dc:publisher.institution
- Department of Human Biology
- Year dc:date.issued
- 2011
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Hess, Aaron T
- Advisors dc:contributor.advisor
-
- Meintjies, Ernesta
- Van der Kouwe, Andre
Subjects
dc:subject × 1Rights
- Language dc:language.iso
- eng
Identifiers
dc:identifier.*- Dc Identifier Apacitation
- Hess, A. T. (2011). <i>Real-time motion and main magnetic field correction in MR spectroscopy using an EPI volumetric navigator</i>. (Thesis). University of Cape Town ,Faculty of Health Sciences ,Department of Human Biology. Retrieved from http://hdl.handle.net/11427/11359
- Dc Identifier Chicagocitation
- Hess, Aaron T. <i>"Real-time motion and main magnetic field correction in MR spectroscopy using an EPI volumetric navigator."</i> Thesis., University of Cape Town ,Faculty of Health Sciences ,Department of Human Biology, 2011. http://hdl.handle.net/11427/11359
- Dc Identifier Citation
- Hess, A. 2011. Real-time motion and main magnetic field correction in MR spectroscopy using an EPI volumetric navigator. University of Cape Town.
- Dc Identifier Ris
- TY - Thesis / Dissertation AU - Hess, Aaron T AB - In population groups where subjects do not lie still during Magnetic Resonance Spectroscopy (MRS) scans, real-time volume of interest (VOI), frequency, and main magnetic field (B0) shim correction may be necessary. This work demonstrates firstly that head movement causes significant B0 disruption in both single voxel spectroscopy and spectroscopic imaging. DA - 2011 DB - OpenUCT DP - University of Cape Town LK - https://open.uct.ac.za PB - University of Cape Town PY - 2011 T1 - Real-time motion and main magnetic field correction in MR spectroscopy using an EPI volumetric navigator TI - Real-time motion and main magnetic field correction in MR spectroscopy using an EPI volumetric navigator UR - http://hdl.handle.net/11427/11359 ER -
- Dc Identifier Vancouvercitation
- Hess AT. Real-time motion and main magnetic field correction in MR spectroscopy using an EPI volumetric navigator. [Thesis]. University of Cape Town ,Faculty of Health Sciences ,Department of Human Biology, 2011 [cited yyyy month dd]. Available from: http://hdl.handle.net/11427/11359