Back to search

Department of Electrical Engineering

Multivariable controller design using pareto front

Abstract

dc:description.abstract

A multivariable thermal system with two inputs and two outputs is investigated. Its inputs are a pair of heaters controlled by a computer while its outputs are temperatures measured by two sensors. The system is fully interactive so two different controller structures can be used to ensure that the temperatures track their respective set-points. Both are multivariable controllers though one has a diagonal structure while the other has a triangular structure. Multi-objective optimization with a posteriori decision-making based on Pareto efficiency, level diagrams, hyper volumes and other performance indices is used to compare quantitatively the two controller structures when applied to a highly interactive multivariable system based on this plant.

Degree

thesis:*
Grantor dc:publisher.institution
Department of Electrical Engineering
Year dc:date.issued
2011

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Ho, Ka Wing
Advisor dc:contributor.advisor
  • Braae, Martin

Subjects

dc:subject × 1

Rights

Language dc:language.iso
eng

Identifiers

dc:identifier.*
Dc Identifier Apacitation
Ho, K. W. (2011). <i>Multivariable controller design using pareto front</i>. (Thesis). University of Cape Town ,Faculty of Engineering & the Built Environment ,Department of Electrical Engineering. Retrieved from http://hdl.handle.net/11427/11751
Dc Identifier Chicagocitation
Ho, Ka Wing. <i>"Multivariable controller design using pareto front."</i> Thesis., University of Cape Town ,Faculty of Engineering & the Built Environment ,Department of Electrical Engineering, 2011. http://hdl.handle.net/11427/11751
Dc Identifier Citation
Ho, K. 2011. Multivariable controller design using pareto front. University of Cape Town.
Dc Identifier Ris
TY - Thesis / Dissertation AU - Ho, Ka Wing AB - A multivariable thermal system with two inputs and two outputs is investigated. Its inputs are a pair of heaters controlled by a computer while its outputs are temperatures measured by two sensors. The system is fully interactive so two different controller structures can be used to ensure that the temperatures track their respective set-points. Both are multivariable controllers though one has a diagonal structure while the other has a triangular structure. Multi-objective optimization with a posteriori decision-making based on Pareto efficiency, level diagrams, hyper volumes and other performance indices is used to compare quantitatively the two controller structures when applied to a highly interactive multivariable system based on this plant. DA - 2011 DB - OpenUCT DP - University of Cape Town LK - https://open.uct.ac.za PB - University of Cape Town PY - 2011 T1 - Multivariable controller design using pareto front TI - Multivariable controller design using pareto front UR - http://hdl.handle.net/11427/11751 ER -
Dc Identifier Vancouvercitation
Ho KW. Multivariable controller design using pareto front. [Thesis]. University of Cape Town ,Faculty of Engineering & the Built Environment ,Department of Electrical Engineering, 2011 [cited yyyy month dd]. Available from: http://hdl.handle.net/11427/11751

Chain of custody

source
Harvested from
University of Cape Town
Base URL
open.uct.ac.za/oai/request
Last updated
2026-11-21
Source record
OAI-PMH GetRecord
citation

Ho, Ka Wing. Multivariable controller design using pareto front. Department of Electrical Engineering, 2011. http://hdl.handle.net/11427/11751