Department of Mechanical Engineering
Asymmetric flow measurement in space constrained cooling water ducts using a traversing probe
Abstract
dc:description.abstractThe aim of this research was to identity and recommend a type of flow measurement technique suitable for flow measurements in the CW ducts. After conducting a literature survey, the author restricted research to a local flow measuring technique as a result of physical constraints on site. In addition, the flow profile in the CW ducts was unknown so that existing flow rate measurement standards could not be applied. Thus the focus of this research was to predict the expected accuracy of local flow measurements in asymmetric flow conditions.
Degree
thesis:*- Grantor dc:publisher.institution
- Department of Mechanical Engineering
- Year dc:date.issued
- 2015
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Mutshinya, Rudzani Allan
- Advisor dc:contributor.advisor
-
- Fuls, Wim
Subjects
dc:subject × 1Rights
- Language dc:language.iso
- eng
Identifiers
dc:identifier.*- Dc Identifier Apacitation
- Mutshinya, R. A. (2015). <i>Asymmetric flow measurement in space constrained cooling water ducts using a traversing probe</i>. (Thesis). University of Cape Town ,Faculty of Engineering & the Built Environment ,Department of Mechanical Engineering. Retrieved from http://hdl.handle.net/11427/13712
- Dc Identifier Chicagocitation
- Mutshinya, Rudzani Allan. <i>"Asymmetric flow measurement in space constrained cooling water ducts using a traversing probe."</i> Thesis., University of Cape Town ,Faculty of Engineering & the Built Environment ,Department of Mechanical Engineering, 2015. http://hdl.handle.net/11427/13712
- Dc Identifier Citation
- Mutshinya, R. 2015. Asymmetric flow measurement in space constrained cooling water ducts using a traversing probe. University of Cape Town.
- Dc Identifier Ris
- TY - Thesis / Dissertation AU - Mutshinya, Rudzani Allan AB - The aim of this research was to identity and recommend a type of flow measurement technique suitable for flow measurements in the CW ducts. After conducting a literature survey, the author restricted research to a local flow measuring technique as a result of physical constraints on site. In addition, the flow profile in the CW ducts was unknown so that existing flow rate measurement standards could not be applied. Thus the focus of this research was to predict the expected accuracy of local flow measurements in asymmetric flow conditions. DA - 2015 DB - OpenUCT DP - University of Cape Town LK - https://open.uct.ac.za PB - University of Cape Town PY - 2015 T1 - Asymmetric flow measurement in space constrained cooling water ducts using a traversing probe TI - Asymmetric flow measurement in space constrained cooling water ducts using a traversing probe UR - http://hdl.handle.net/11427/13712 ER -
- Dc Identifier Vancouvercitation
- Mutshinya RA. Asymmetric flow measurement in space constrained cooling water ducts using a traversing probe. [Thesis]. University of Cape Town ,Faculty of Engineering & the Built Environment ,Department of Mechanical Engineering, 2015 [cited yyyy month dd]. Available from: http://hdl.handle.net/11427/13712