Back to search

Department of Electrical Engineering

Non-intrusive efficiency estimation of induction machines under various power supplies

Abstract

dc:description.abstract

Considering that 45% of the world's generated electricity is consumed by induction machines, determining an induction motors efficiency non-intrusively is of great importance in that it enables the machine to operate productively whilst ensuring that the energy consumed by the machine is utilized efficiently. International efficiency testing methods such as the IEEE 112-B can determine a motors efficiency accurately at the cost of hindering the machines productivity. Alternatively, various methods used to determine a machines efficiency in-situ do so at the cost of accuracy. This research proposes a method that determines an induction machines efficiency over a range of load conditions from tests conducted and centered around one thermally stable load point in the least intrusive manner possible. Coupled with vibration sensors used to determine a motor's speed, measured input voltages and currents are used to deduce a machine efficiency-load profile through the use of a modified evolutionary algorithm, the Non-Intrusive Efficiency Estimation using Population-Based Incremental Learning(NIEE-PBIL) algorithm. Five temporal load measurements are taken, centered around one thermally stable load point, to determine the machines efficiency profile from two equivalent circuit implementations; the Standard Circuit NIEE-PBIL and the Iron-Loss NIEE-PBIL.

Degree

thesis:*
Grantor dc:publisher.institution
Department of Electrical Engineering
Year dc:date.issued
2013

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Gajjar, Chetan Sudhir
Advisors dc:contributor.advisor
  • Khan, Azeem
  • Barendse, Paul Stanley

Subjects

dc:subject × 1

Rights

Language dc:language.iso
eng

Identifiers

dc:identifier.*
Dc Identifier Apacitation
Gajjar, C. S. (2013). <i>Non-intrusive efficiency estimation of induction machines under various power supplies</i>. (Thesis). University of Cape Town ,Faculty of Engineering & the Built Environment ,Department of Electrical Engineering. Retrieved from http://hdl.handle.net/11427/14138
Dc Identifier Chicagocitation
Gajjar, Chetan Sudhir. <i>"Non-intrusive efficiency estimation of induction machines under various power supplies."</i> Thesis., University of Cape Town ,Faculty of Engineering & the Built Environment ,Department of Electrical Engineering, 2013. http://hdl.handle.net/11427/14138
Dc Identifier Citation
Gajjar, C. 2013. Non-intrusive efficiency estimation of induction machines under various power supplies. University of Cape Town.
Dc Identifier Ris
TY - Thesis / Dissertation AU - Gajjar, Chetan Sudhir AB - Considering that 45% of the world's generated electricity is consumed by induction machines, determining an induction motors efficiency non-intrusively is of great importance in that it enables the machine to operate productively whilst ensuring that the energy consumed by the machine is utilized efficiently. International efficiency testing methods such as the IEEE 112-B can determine a motors efficiency accurately at the cost of hindering the machines productivity. Alternatively, various methods used to determine a machines efficiency in-situ do so at the cost of accuracy. This research proposes a method that determines an induction machines efficiency over a range of load conditions from tests conducted and centered around one thermally stable load point in the least intrusive manner possible. Coupled with vibration sensors used to determine a motor's speed, measured input voltages and currents are used to deduce a machine efficiency-load profile through the use of a modified evolutionary algorithm, the Non-Intrusive Efficiency Estimation using Population-Based Incremental Learning(NIEE-PBIL) algorithm. Five temporal load measurements are taken, centered around one thermally stable load point, to determine the machines efficiency profile from two equivalent circuit implementations; the Standard Circuit NIEE-PBIL and the Iron-Loss NIEE-PBIL. DA - 2013 DB - OpenUCT DP - University of Cape Town LK - https://open.uct.ac.za PB - University of Cape Town PY - 2013 T1 - Non-intrusive efficiency estimation of induction machines under various power supplies TI - Non-intrusive efficiency estimation of induction machines under various power supplies UR - http://hdl.handle.net/11427/14138 ER -
Dc Identifier Vancouvercitation
Gajjar CS. Non-intrusive efficiency estimation of induction machines under various power supplies. [Thesis]. University of Cape Town ,Faculty of Engineering & the Built Environment ,Department of Electrical Engineering, 2013 [cited yyyy month dd]. Available from: http://hdl.handle.net/11427/14138

Chain of custody

source
Harvested from
University of Cape Town
Base URL
open.uct.ac.za/oai/request
Last updated
2026-11-25
Source record
OAI-PMH GetRecord
citation

Gajjar, Chetan Sudhir. Non-intrusive efficiency estimation of induction machines under various power supplies. Department of Electrical Engineering, 2013. https://hdl.handle.net/11427/14138