Back to search

Department of Anaesthesia

A cost comparison of spontaneously ventilated patients: the universal anaesthesia machine as a possible cost effective alternative

Abstract

dc:description.abstract

Background: A new appreciation of relevant risks, as well as the increased availability of technologies that facilitate the use of regional techniques, have increased the number of patients that are allowed to breathe spontaneously during their procedures. The ever-growing caseload of surgical patients in resource poor environments demands an anaesthetic service and equipment capable of meeting with these demands. Methods: Patients were recruited to receive their general anaesthesia by means of either the Universal Anaesthesia Machine (UAM) or the standard plenum system available. Anaesthesia was administered according to a protocol and the consumption of electricity, carrier gases, volatile hypnotic agent and carbon dioxide absorbent was measured. The cost per minute was then calculated for each device respectively. Results: Our study recruited 50 patients (25 into each group) across several surgical specialties. We found that when calculated as a total South African Rand (ZAR) per minute cost (for our centre) the UAM was statistically significantly more expensive (R 0.974/min vs. R 0.459/min, p < 0,00001). We were able to derive equations to predict the cost consumption of the respective devices, allowing the use of this data in a wide array of clinical settings. Conclusion: Whilst our finding is by no means surprising, it allowed us to produce formulae by which individual centres can calculate the implications of each option using the specific costs of the various consumables available to them.

Degree

thesis:*
Grantor dc:publisher.institution
Department of Anaesthesia
Year dc:date.issued
2015

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Van Rensburg, G P
Advisors dc:contributor.advisor
  • Nieuwveld, Robert
  • James, Michael Frank Mansel

Subjects

dc:subject × 1

Rights

Language dc:language.iso
eng

Identifiers

dc:identifier.*
Dc Identifier Apacitation
Van Rensburg, G. P. (2015). <i>A cost comparison of spontaneously ventilated patients: the universal anaesthesia machine as a possible cost effective alternative</i>. (Thesis). University of Cape Town ,Faculty of Health Sciences ,Department of Anaesthesia. Retrieved from http://hdl.handle.net/11427/16930
Dc Identifier Chicagocitation
Van Rensburg, G P. <i>"A cost comparison of spontaneously ventilated patients: the universal anaesthesia machine as a possible cost effective alternative."</i> Thesis., University of Cape Town ,Faculty of Health Sciences ,Department of Anaesthesia, 2015. http://hdl.handle.net/11427/16930
Dc Identifier Citation
Van Rensburg, G. 2015. A cost comparison of spontaneously ventilated patients: the universal anaesthesia machine as a possible cost effective alternative. University of Cape Town.
Dc Identifier Ris
TY - Thesis / Dissertation AU - Van Rensburg, G P AB - Background: A new appreciation of relevant risks, as well as the increased availability of technologies that facilitate the use of regional techniques, have increased the number of patients that are allowed to breathe spontaneously during their procedures. The ever-growing caseload of surgical patients in resource poor environments demands an anaesthetic service and equipment capable of meeting with these demands. Methods: Patients were recruited to receive their general anaesthesia by means of either the Universal Anaesthesia Machine (UAM) or the standard plenum system available. Anaesthesia was administered according to a protocol and the consumption of electricity, carrier gases, volatile hypnotic agent and carbon dioxide absorbent was measured. The cost per minute was then calculated for each device respectively. Results: Our study recruited 50 patients (25 into each group) across several surgical specialties. We found that when calculated as a total South African Rand (ZAR) per minute cost (for our centre) the UAM was statistically significantly more expensive (R 0.974/min vs. R 0.459/min, p < 0,00001). We were able to derive equations to predict the cost consumption of the respective devices, allowing the use of this data in a wide array of clinical settings. Conclusion: Whilst our finding is by no means surprising, it allowed us to produce formulae by which individual centres can calculate the implications of each option using the specific costs of the various consumables available to them. DA - 2015 DB - OpenUCT DP - University of Cape Town LK - https://open.uct.ac.za PB - University of Cape Town PY - 2015 T1 - A cost comparison of spontaneously ventilated patients: the universal anaesthesia machine as a possible cost effective alternative TI - A cost comparison of spontaneously ventilated patients: the universal anaesthesia machine as a possible cost effective alternative UR - http://hdl.handle.net/11427/16930 ER -
Dc Identifier Vancouvercitation
Van Rensburg GP. A cost comparison of spontaneously ventilated patients: the universal anaesthesia machine as a possible cost effective alternative. [Thesis]. University of Cape Town ,Faculty of Health Sciences ,Department of Anaesthesia, 2015 [cited yyyy month dd]. Available from: http://hdl.handle.net/11427/16930

Chain of custody

source
Harvested from
University of Cape Town
Base URL
open.uct.ac.za/oai/request
Last updated
2026-11-25
Source record
OAI-PMH GetRecord
citation

Van Rensburg, G P. A cost comparison of spontaneously ventilated patients: the universal anaesthesia machine as a possible cost effective alternative. Department of Anaesthesia, 2015. https://hdl.handle.net/11427/16930