Back to search

Department of Electrical Engineering

Influence of higher time harmonics on the electrical and mechanical performance of an inverter-fed squirrel cage induction motor

Abstract

dc:description.abstract

Due to the ruggedness, reliability and low maintenance required, small inverter-fed induction motors (1.5 kW to 25 kW) have earned a reputation and are utilized more and more frequently in industry for variable speed applications. The applied voltage and current waveforms are generally quite non-sinusoidal and polluted with higher time harmonic components. The higher time harmonics affect the electrical and mechanical performance significantly, and adverse effects are investigated. Literature on the effect of higher time harmonics is reviewed. Recommendations referring to various aspects under non-sinusoidal excitation are made when installing inverter-fed induction motors. Different inverter supplies (6-Pulse Square Wave voltage source inverter (VSI), PWM VSI and sinusoidal excitation) are used with a small 3-Phase, 3-kW squirrel cage induction motor, configured under synchronous characteristic Vᵣ/50 and subsynchronous characteristic Vᵣ/87. The respective voltage and current frequency spectrums of the excitation source are analyzed and the harmonic content determined. Performance executed under identical operating respectively and results are compared with pure sinusoidal (fundamental) excitation. tests are conditions respect to To determine the electrical performance the efficiency, power factor, temperature rise of the stator and induced shaft voltages were analyzed. The mechanical performance under inverter operation was analyzed by measuring the torque, torque pulsations, critical speeds and resonance frequencies of frame vibrations and torque oscillations as well as vibrations in x-, y-, and z-direction of the inverter-fed induction machine. Consequences of time harmonics on the induction motor and system are discussed. Conclusions on the effect of time harmonics and performance of different inverter types compared to sinusoidal excitation are drawn and are theoretically summarized and justified. Summary in English and German. Bibliography: pages 148-154.

Degree

thesis:*
Grantor dc:publisher.institution
Department of Electrical Engineering
Year dc:date.issued
1991

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Roeber, Jochen Erich
Advisor dc:contributor.advisor
  • Gieras, Jacek F

Subjects

dc:subject × 1

Rights

Language dc:language.iso
eng

Identifiers

dc:identifier.*
Dc Identifier Apacitation
Roeber, J. E. (1991). <i>Influence of higher time harmonics on the electrical and mechanical performance of an inverter-fed squirrel cage induction motor</i>. (Thesis). University of Cape Town ,Faculty of Engineering & the Built Environment ,Department of Electrical Engineering. Retrieved from http://hdl.handle.net/11427/19507
Dc Identifier Chicagocitation
Roeber, Jochen Erich. <i>"Influence of higher time harmonics on the electrical and mechanical performance of an inverter-fed squirrel cage induction motor."</i> Thesis., University of Cape Town ,Faculty of Engineering & the Built Environment ,Department of Electrical Engineering, 1991. http://hdl.handle.net/11427/19507
Dc Identifier Citation
Roeber, J. 1991. Influence of higher time harmonics on the electrical and mechanical performance of an inverter-fed squirrel cage induction motor. University of Cape Town.
Dc Identifier Ris
TY - Thesis / Dissertation AU - Roeber, Jochen Erich AB - Due to the ruggedness, reliability and low maintenance required, small inverter-fed induction motors (1.5 kW to 25 kW) have earned a reputation and are utilized more and more frequently in industry for variable speed applications. The applied voltage and current waveforms are generally quite non-sinusoidal and polluted with higher time harmonic components. The higher time harmonics affect the electrical and mechanical performance significantly, and adverse effects are investigated. Literature on the effect of higher time harmonics is reviewed. Recommendations referring to various aspects under non-sinusoidal excitation are made when installing inverter-fed induction motors. Different inverter supplies (6-Pulse Square Wave voltage source inverter (VSI), PWM VSI and sinusoidal excitation) are used with a small 3-Phase, 3-kW squirrel cage induction motor, configured under synchronous characteristic Vᵣ/50 and subsynchronous characteristic Vᵣ/87. The respective voltage and current frequency spectrums of the excitation source are analyzed and the harmonic content determined. Performance executed under identical operating respectively and results are compared with pure sinusoidal (fundamental) excitation. tests are conditions respect to To determine the electrical performance the efficiency, power factor, temperature rise of the stator and induced shaft voltages were analyzed. The mechanical performance under inverter operation was analyzed by measuring the torque, torque pulsations, critical speeds and resonance frequencies of frame vibrations and torque oscillations as well as vibrations in x-, y-, and z-direction of the inverter-fed induction machine. Consequences of time harmonics on the induction motor and system are discussed. Conclusions on the effect of time harmonics and performance of different inverter types compared to sinusoidal excitation are drawn and are theoretically summarized and justified. Summary in English and German. Bibliography: pages 148-154. DA - 1991 DB - OpenUCT DP - University of Cape Town LK - https://open.uct.ac.za PB - University of Cape Town PY - 1991 T1 - Influence of higher time harmonics on the electrical and mechanical performance of an inverter-fed squirrel cage induction motor TI - Influence of higher time harmonics on the electrical and mechanical performance of an inverter-fed squirrel cage induction motor UR - http://hdl.handle.net/11427/19507 ER -
Dc Identifier Vancouvercitation
Roeber JE. Influence of higher time harmonics on the electrical and mechanical performance of an inverter-fed squirrel cage induction motor. [Thesis]. University of Cape Town ,Faculty of Engineering & the Built Environment ,Department of Electrical Engineering, 1991 [cited yyyy month dd]. Available from: http://hdl.handle.net/11427/19507

Chain of custody

source
Harvested from
University of Cape Town
Base URL
open.uct.ac.za/oai/request
Last updated
2026-11-20
Source record
OAI-PMH GetRecord
citation

Roeber, Jochen Erich. Influence of higher time harmonics on the electrical and mechanical performance of an inverter-fed squirrel cage induction motor. Department of Electrical Engineering, 1991. https://hdl.handle.net/11427/19507