Back to search

Department of Mechanical Engineering

The in-service non-destructive evaluation of wooden transmission line poles

Abstract

dc:description.abstract

This thesis covers the research undertaken on behalf of the ESKOM TRI Group into the In-service Non-Destructive Evaluation of Wooden Transmission Line Poles. The aim of this work was the development of an effective pole tester that could be used to test the integrity of wooden transmission line poles in situ. The pole testing method that ESKOM uses at present is both time and labour intensive and it is envisaged that this research will contribute to the establishment of a faster, cheaper and more effective alternative. The research began with a literature survey of past investigations. Previous research in this area followed two distinct approaches. The first approach concentrated on mechanical testing procedures. For example the physical bending of the pole and measuring its bending stress (the effect that this bending has on the single fibres in the pole is not documented). The present ESKOM pole tester follows this approach. The second approach has been in the field of true "non-destructive" testing. Procedures using x-rays, magnetic resonance imaging and vibration analysis have all been considered in the past by investigators. The present investigation followed the approach of vibrations analysis. The process involved impacting the pole and measuring its vibration response. The response was then used to analyse the pole's behaviour. The state of integrity of the pole determined its vibration characteristics.

Degree

thesis:*
Grantor dc:publisher.institution
Department of Mechanical Engineering
Year dc:date.issued
1998

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Prestage, Brendan Paul
Advisor dc:contributor.advisor
  • Gryzagoridis, Jasson

Subjects

dc:subject × 1

Rights

Language dc:language.iso
eng

Identifiers

dc:identifier.*
Dc Identifier Apacitation
Prestage, B. P. (1998). <i>The in-service non-destructive evaluation of wooden transmission line poles</i>. (Thesis). University of Cape Town ,Faculty of Engineering & the Built Environment ,Department of Mechanical Engineering. Retrieved from http://hdl.handle.net/11427/21340
Dc Identifier Chicagocitation
Prestage, Brendan Paul. <i>"The in-service non-destructive evaluation of wooden transmission line poles."</i> Thesis., University of Cape Town ,Faculty of Engineering & the Built Environment ,Department of Mechanical Engineering, 1998. http://hdl.handle.net/11427/21340
Dc Identifier Citation
Prestage, B. 1998. The in-service non-destructive evaluation of wooden transmission line poles. University of Cape Town.
Dc Identifier Ris
TY - Thesis / Dissertation AU - Prestage, Brendan Paul AB - This thesis covers the research undertaken on behalf of the ESKOM TRI Group into the In-service Non-Destructive Evaluation of Wooden Transmission Line Poles. The aim of this work was the development of an effective pole tester that could be used to test the integrity of wooden transmission line poles in situ. The pole testing method that ESKOM uses at present is both time and labour intensive and it is envisaged that this research will contribute to the establishment of a faster, cheaper and more effective alternative. The research began with a literature survey of past investigations. Previous research in this area followed two distinct approaches. The first approach concentrated on mechanical testing procedures. For example the physical bending of the pole and measuring its bending stress (the effect that this bending has on the single fibres in the pole is not documented). The present ESKOM pole tester follows this approach. The second approach has been in the field of true "non-destructive" testing. Procedures using x-rays, magnetic resonance imaging and vibration analysis have all been considered in the past by investigators. The present investigation followed the approach of vibrations analysis. The process involved impacting the pole and measuring its vibration response. The response was then used to analyse the pole's behaviour. The state of integrity of the pole determined its vibration characteristics. DA - 1998 DB - OpenUCT DP - University of Cape Town LK - https://open.uct.ac.za PB - University of Cape Town PY - 1998 T1 - The in-service non-destructive evaluation of wooden transmission line poles TI - The in-service non-destructive evaluation of wooden transmission line poles UR - http://hdl.handle.net/11427/21340 ER -
Dc Identifier Vancouvercitation
Prestage BP. The in-service non-destructive evaluation of wooden transmission line poles. [Thesis]. University of Cape Town ,Faculty of Engineering & the Built Environment ,Department of Mechanical Engineering, 1998 [cited yyyy month dd]. Available from: http://hdl.handle.net/11427/21340

Chain of custody

source
Harvested from
University of Cape Town
Base URL
open.uct.ac.za/oai/request
Last updated
2026-11-25
Source record
OAI-PMH GetRecord
citation

Prestage, Brendan Paul. The in-service non-destructive evaluation of wooden transmission line poles. Department of Mechanical Engineering, 1998. https://hdl.handle.net/11427/21340