Back to search

Department of Electrical Engineering

Control and monitoring of an intra-aortic balloon pump for cardiac assist

Abstract

dc:description.abstract

An anatomical and physiological background to the heart as a pump, followed by a description of the causes and results of cardiogenic shock is given. A survey of the achievements of other researchers in this field is included. The design of a system for controlling and monitoring the Intra-Aortic Balloon Pump is described. A narrow band-pass filter is used to reduce noise and limit the input to the detector to the spectrum within which the R-wave of an ECG signal lies. A safety circuit to prevent the heart pumping against an inflated balloon is incorporated. History of the 8 secs preceding any instant is available. A description of the medical tests carried out so far is given.

Degree

thesis:*
Grantor dc:publisher.institution
Department of Electrical Engineering
Year dc:date.issued
1971

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Holmes à Court, Robert Leonard
Advisor dc:contributor.advisor
  • Besseling, Johann L N

Subjects

dc:subject × 2

Rights

Language dc:language.iso
eng

Identifiers

dc:identifier.*
Dc Identifier Apacitation
Holmes à Court, R. L. (1971). <i>Control and monitoring of an intra-aortic balloon pump for cardiac assist</i>. (Thesis). University of Cape Town ,Faculty of Engineering & the Built Environment ,Department of Electrical Engineering. Retrieved from http://hdl.handle.net/11427/22178
Dc Identifier Chicagocitation
Holmes à Court, Robert Leonard. <i>"Control and monitoring of an intra-aortic balloon pump for cardiac assist."</i> Thesis., University of Cape Town ,Faculty of Engineering & the Built Environment ,Department of Electrical Engineering, 1971. http://hdl.handle.net/11427/22178
Dc Identifier Citation
Holmes à Court, R. 1971. Control and monitoring of an intra-aortic balloon pump for cardiac assist. University of Cape Town.
Dc Identifier Ris
TY - Thesis / Dissertation AU - Holmes à Court, Robert Leonard AB - An anatomical and physiological background to the heart as a pump, followed by a description of the causes and results of cardiogenic shock is given. A survey of the achievements of other researchers in this field is included. The design of a system for controlling and monitoring the Intra-Aortic Balloon Pump is described. A narrow band-pass filter is used to reduce noise and limit the input to the detector to the spectrum within which the R-wave of an ECG signal lies. A safety circuit to prevent the heart pumping against an inflated balloon is incorporated. History of the 8 secs preceding any instant is available. A description of the medical tests carried out so far is given. DA - 1971 DB - OpenUCT DP - University of Cape Town LK - https://open.uct.ac.za PB - University of Cape Town PY - 1971 T1 - Control and monitoring of an intra-aortic balloon pump for cardiac assist TI - Control and monitoring of an intra-aortic balloon pump for cardiac assist UR - http://hdl.handle.net/11427/22178 ER -
Dc Identifier Vancouvercitation
Holmes à Court RL. Control and monitoring of an intra-aortic balloon pump for cardiac assist. [Thesis]. University of Cape Town ,Faculty of Engineering & the Built Environment ,Department of Electrical Engineering, 1971 [cited yyyy month dd]. Available from: http://hdl.handle.net/11427/22178

Chain of custody

source
Harvested from
University of Cape Town
Base URL
open.uct.ac.za/oai/request
Last updated
2026-11-21
Source record
OAI-PMH GetRecord
citation

Holmes à Court, Robert Leonard. Control and monitoring of an intra-aortic balloon pump for cardiac assist. Department of Electrical Engineering, 1971. http://hdl.handle.net/11427/22178