Back to search

Centre for Research in Computational and Applied Mechanics (CERECAM)

Fluid-structure interaction modelling of a patient-specific arteriovenous access fistula

Abstract

dc:description.abstract

This research forms part of an interdisciplinary project that aims to improve the detailed understanding of the haemodynamics and vascular mechanics in arteriovenous shunts that are required for haemodialysis treatments. A combination of new PCMRA imaging and computational modelling of in vivo blood flow aims to determine the haemodynamic conditions that may lead to the high failure rate of vascular access in these circumstances. This thesis focuses on developing a patient-specific fluid-structure interaction (FSI) model of a PC-MRA imaged arteriovenous fistula. The numerical FSI model is developed and simulated within the commercial multiphysics simulation package ANSYS® Academic Research, Release 16. The blood flow is modelled as a Newtonian fluid with the finite-volume method solver ANSYS® Fluent®. A pulsatile mass-flow boundary condition is applied at the artery inlet and a three-element Windkessel model at the artery and vein outlets. ANSYS® Mechanical™, a finite element method solver, is used to model the nonlinear behaviour of the vessel walls. The artery and vein walls are assumed to follow a third-order Yeoh model, and are differentiated by thickness and by material strength characteristics. The staggered FSI model is configured and executed in ANSYS® Workbench™, forming a semi-implicit coupling of the blood flow and vessel wall models. This work shows the effectiveness of combining a number of stabilisation techniques to simultaneously overcome the added-mass effect and optimise the efficiency of the overall model. The PC-MRA data, fluid model, and FSI model show almost identical flow features in the fistula; this applies in particular to a flow recirculation region in the vein that could potentially lead to fistula failure.

Degree

thesis:*
Grantor dc:publisher.institution
Centre for Research in Computational and Applied Mechanics (CERECAM)
Year dc:date.issued
2016

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Guess, Winston
Advisors dc:contributor.advisor
  • Reddy, B Daya
  • McBride, Andrew Trevor

Subjects

dc:subject × 1

Rights

Language dc:language.iso
eng

Identifiers

dc:identifier.*
Dc Identifier Apacitation
Guess, W. (2016). <i>Fluid-structure interaction modelling of a patient-specific arteriovenous access fistula</i>. (Thesis). University of Cape Town ,Faculty of Engineering & the Built Environment ,Centre for Research in Computational and Applied Mechanics (CERECAM). Retrieved from http://hdl.handle.net/11427/22840
Dc Identifier Chicagocitation
Guess, Winston. <i>"Fluid-structure interaction modelling of a patient-specific arteriovenous access fistula."</i> Thesis., University of Cape Town ,Faculty of Engineering & the Built Environment ,Centre for Research in Computational and Applied Mechanics (CERECAM), 2016. http://hdl.handle.net/11427/22840
Dc Identifier Citation
Guess, W. 2016. Fluid-structure interaction modelling of a patient-specific arteriovenous access fistula. University of Cape Town.
Dc Identifier Ris
TY - Thesis / Dissertation AU - Guess, Winston AB - This research forms part of an interdisciplinary project that aims to improve the detailed understanding of the haemodynamics and vascular mechanics in arteriovenous shunts that are required for haemodialysis treatments. A combination of new PCMRA imaging and computational modelling of in vivo blood flow aims to determine the haemodynamic conditions that may lead to the high failure rate of vascular access in these circumstances. This thesis focuses on developing a patient-specific fluid-structure interaction (FSI) model of a PC-MRA imaged arteriovenous fistula. The numerical FSI model is developed and simulated within the commercial multiphysics simulation package ANSYS® Academic Research, Release 16. The blood flow is modelled as a Newtonian fluid with the finite-volume method solver ANSYS® Fluent®. A pulsatile mass-flow boundary condition is applied at the artery inlet and a three-element Windkessel model at the artery and vein outlets. ANSYS® Mechanical™, a finite element method solver, is used to model the nonlinear behaviour of the vessel walls. The artery and vein walls are assumed to follow a third-order Yeoh model, and are differentiated by thickness and by material strength characteristics. The staggered FSI model is configured and executed in ANSYS® Workbench™, forming a semi-implicit coupling of the blood flow and vessel wall models. This work shows the effectiveness of combining a number of stabilisation techniques to simultaneously overcome the added-mass effect and optimise the efficiency of the overall model. The PC-MRA data, fluid model, and FSI model show almost identical flow features in the fistula; this applies in particular to a flow recirculation region in the vein that could potentially lead to fistula failure. DA - 2016 DB - OpenUCT DP - University of Cape Town LK - https://open.uct.ac.za PB - University of Cape Town PY - 2016 T1 - Fluid-structure interaction modelling of a patient-specific arteriovenous access fistula TI - Fluid-structure interaction modelling of a patient-specific arteriovenous access fistula UR - http://hdl.handle.net/11427/22840 ER -
Dc Identifier Vancouvercitation
Guess W. Fluid-structure interaction modelling of a patient-specific arteriovenous access fistula. [Thesis]. University of Cape Town ,Faculty of Engineering & the Built Environment ,Centre for Research in Computational and Applied Mechanics (CERECAM), 2016 [cited yyyy month dd]. Available from: http://hdl.handle.net/11427/22840

Chain of custody

source
Harvested from
University of Cape Town
Base URL
open.uct.ac.za/oai/request
Last updated
2026-11-20
Source record
OAI-PMH GetRecord
citation