Back to search

Division of Biomedical Engineering

A system for the acquisition and digital analysis of lower limb flow waveforms

Abstract

dc:description.abstract

A PC based waveform acquisition and analysis system has been developed for use in aorta-iliac arterial assessment. A Motorola DSP56001 based system containing dual Analog to Digital converters is used to sample phase quadrature demodulated signals from a commercially available continuous wave Doppler unit. The Power Spectral Density is calculated using an autoregressive model from which the mean velocity waveform is calculated. This waveform is used to calculate the damping factor, vessel compliance and runoff resistance of a simple electrical model of the lower limb arterial circulation using a non-linear regression technique of curve fitting in the time domain. A pilot study using the system shows a significant separation (p < 0.001 Mann Whitney U-test) between the damping factors of a normal control group (quartile range = 0. 15 - 0.25 ; median = 0. 19) and a patient group with angiographically determined aorta-iliac arterial disease (quartile range = 0.45 - 0.89 ; median= 0.49).

Degree

thesis:*
Grantor dc:publisher.institution
Division of Biomedical Engineering
Year dc:date.issued
1994

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Smith, Leonard
Advisors dc:contributor.advisor
  • Capper, Wayne L
  • Bunn, Anthony E
  • Immelman, E J

Subjects

dc:subject × 3

Rights

Language dc:language.iso
eng

Identifiers

dc:identifier.*
Dc Identifier Apacitation
Smith, L. (1994). <i>A system for the acquisition and digital analysis of lower limb flow waveforms</i>. (Thesis). University of Cape Town ,Faculty of Health Sciences ,Division of Biomedical Engineering. Retrieved from http://hdl.handle.net/11427/27049
Dc Identifier Chicagocitation
Smith, Leonard. <i>"A system for the acquisition and digital analysis of lower limb flow waveforms."</i> Thesis., University of Cape Town ,Faculty of Health Sciences ,Division of Biomedical Engineering, 1994. http://hdl.handle.net/11427/27049
Dc Identifier Citation
Smith, L. 1994. A system for the acquisition and digital analysis of lower limb flow waveforms. University of Cape Town.
Dc Identifier Ris
TY - Thesis / Dissertation AU - Smith, Leonard AB - A PC based waveform acquisition and analysis system has been developed for use in aorta-iliac arterial assessment. A Motorola DSP56001 based system containing dual Analog to Digital converters is used to sample phase quadrature demodulated signals from a commercially available continuous wave Doppler unit. The Power Spectral Density is calculated using an autoregressive model from which the mean velocity waveform is calculated. This waveform is used to calculate the damping factor, vessel compliance and runoff resistance of a simple electrical model of the lower limb arterial circulation using a non-linear regression technique of curve fitting in the time domain. A pilot study using the system shows a significant separation (p < 0.001 Mann Whitney U-test) between the damping factors of a normal control group (quartile range = 0. 15 - 0.25 ; median = 0. 19) and a patient group with angiographically determined aorta-iliac arterial disease (quartile range = 0.45 - 0.89 ; median= 0.49). DA - 1994 DB - OpenUCT DP - University of Cape Town LK - https://open.uct.ac.za PB - University of Cape Town PY - 1994 T1 - A system for the acquisition and digital analysis of lower limb flow waveforms TI - A system for the acquisition and digital analysis of lower limb flow waveforms UR - http://hdl.handle.net/11427/27049 ER -
Dc Identifier Vancouvercitation
Smith L. A system for the acquisition and digital analysis of lower limb flow waveforms. [Thesis]. University of Cape Town ,Faculty of Health Sciences ,Division of Biomedical Engineering, 1994 [cited yyyy month dd]. Available from: http://hdl.handle.net/11427/27049