Division of Medical Physics
The use of thermoluminescent dosimeters for In-vivo dosimetry in a fast neutron therapy beam
Abstract
dc:description.abstractThermoluminescent detectors (TLD-700) have been investigated for absorbed dose measurements in a p(66)/Be neutron therapy beam at the National Accelerator Centre. Chips were selected based on their reproducibility and chip individual neutron calibration factors were derived. The dose non-linearity was determined in peak 5 and peak 6 and dose non-linearity corrections were performed. The sensitivity of TLD-700 chips with depth and off-axis distance was determined. In-vivo dose measurements were performed on seven patients (9 fields). In the entrance in-vivo dose measurements, a maximal deviation of 3.2 % was detected and a systematic difference of 1.7 % was observed. On the exit side, a maximal deviation of -7.3 % was detected and a systematic difference of -5.1 % was observed. The glow curve peak 6/5 ratio was investigated and found to correlate with the qualitative variations of the average LET in the neutron beam.
Degree
thesis:*- Grantor dc:publisher.institution
- Division of Medical Physics
- Year dc:date.issued
- 2000
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Bhengu, Khumbulani John
- Advisors dc:contributor.advisor
-
- Jones, Dan T L
- Langen, Katja M
Subjects
dc:subject × 1Rights
- Language dc:language.iso
- eng
Identifiers
dc:identifier.*- Dc Identifier Apacitation
- Bhengu, K. J. (2000). <i>The use of thermoluminescent dosimeters for In-vivo dosimetry in a fast neutron therapy beam</i>. (Thesis). University of Cape Town ,Faculty of Health Sciences ,Division of Medical Physics. Retrieved from http://hdl.handle.net/11427/2799
- Dc Identifier Chicagocitation
- Bhengu, Khumbulani John. <i>"The use of thermoluminescent dosimeters for In-vivo dosimetry in a fast neutron therapy beam."</i> Thesis., University of Cape Town ,Faculty of Health Sciences ,Division of Medical Physics, 2000. http://hdl.handle.net/11427/2799
- Dc Identifier Citation
- Bhengu, K. 2000. The use of thermoluminescent dosimeters for In-vivo dosimetry in a fast neutron therapy beam. University of Cape Town.
- Dc Identifier Ris
- TY - Thesis / Dissertation AU - Bhengu, Khumbulani John AB - Thermoluminescent detectors (TLD-700) have been investigated for absorbed dose measurements in a p(66)/Be neutron therapy beam at the National Accelerator Centre. Chips were selected based on their reproducibility and chip individual neutron calibration factors were derived. The dose non-linearity was determined in peak 5 and peak 6 and dose non-linearity corrections were performed. The sensitivity of TLD-700 chips with depth and off-axis distance was determined. In-vivo dose measurements were performed on seven patients (9 fields). In the entrance in-vivo dose measurements, a maximal deviation of 3.2 % was detected and a systematic difference of 1.7 % was observed. On the exit side, a maximal deviation of -7.3 % was detected and a systematic difference of -5.1 % was observed. The glow curve peak 6/5 ratio was investigated and found to correlate with the qualitative variations of the average LET in the neutron beam. DA - 2000 DB - OpenUCT DP - University of Cape Town LK - https://open.uct.ac.za PB - University of Cape Town PY - 2000 T1 - The use of thermoluminescent dosimeters for In-vivo dosimetry in a fast neutron therapy beam TI - The use of thermoluminescent dosimeters for In-vivo dosimetry in a fast neutron therapy beam UR - http://hdl.handle.net/11427/2799 ER -
- Dc Identifier Vancouvercitation
- Bhengu KJ. The use of thermoluminescent dosimeters for In-vivo dosimetry in a fast neutron therapy beam. [Thesis]. University of Cape Town ,Faculty of Health Sciences ,Division of Medical Physics, 2000 [cited yyyy month dd]. Available from: http://hdl.handle.net/11427/2799