Back to search

Division of Orthopaedic Surgery

Locking plates for distal femur fractures does an increased working length improve healing?

Abstract

dc:description.abstract

Distal femur locking plates have become a very popular means of internal fixation because of their ability to provide stable distal periarticular fixation. In spite of this enthusiasm however several studies have reported significant problems with healing. In the distal femur it is recognized that locking plate fixation may be too rigid if used in certain configurations that limit the essential micro movement required for biological healing. Implant failure may arise from rigid configurations that cause excessive hardware stress concentrations. In an attempt to address these problems longer plates and an increased working length have been proposed to reduce construct rigidity. The purpose of our study is to investigate whether an increased working length translates into improved healing.

Degree

thesis:*
Grantor dc:publisher.institution
Division of Orthopaedic Surgery
Year dc:date.issued
2013

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Koller, Ian M
Advisors dc:contributor.advisor
  • Maqungo, S
  • Walters, J

Subjects

dc:subject × 1

Rights

Language dc:language.iso
eng

Identifiers

dc:identifier.*
Dc Identifier Apacitation
Koller, I. M. (2013). <i>Locking plates for distal femur fractures does an increased working length improve healing?</i>. (Thesis). University of Cape Town ,Faculty of Health Sciences ,Division of Orthopaedic Surgery. Retrieved from http://hdl.handle.net/11427/2844
Dc Identifier Chicagocitation
Koller, Ian M. <i>"Locking plates for distal femur fractures does an increased working length improve healing?."</i> Thesis., University of Cape Town ,Faculty of Health Sciences ,Division of Orthopaedic Surgery, 2013. http://hdl.handle.net/11427/2844
Dc Identifier Citation
Koller, I. 2013. Locking plates for distal femur fractures does an increased working length improve healing?. University of Cape Town.
Dc Identifier Ris
TY - Thesis / Dissertation AU - Koller, Ian M AB - Distal femur locking plates have become a very popular means of internal fixation because of their ability to provide stable distal periarticular fixation. In spite of this enthusiasm however several studies have reported significant problems with healing. In the distal femur it is recognized that locking plate fixation may be too rigid if used in certain configurations that limit the essential micro movement required for biological healing. Implant failure may arise from rigid configurations that cause excessive hardware stress concentrations. In an attempt to address these problems longer plates and an increased working length have been proposed to reduce construct rigidity. The purpose of our study is to investigate whether an increased working length translates into improved healing. DA - 2013 DB - OpenUCT DP - University of Cape Town LK - https://open.uct.ac.za PB - University of Cape Town PY - 2013 T1 - Locking plates for distal femur fractures does an increased working length improve healing? TI - Locking plates for distal femur fractures does an increased working length improve healing? UR - http://hdl.handle.net/11427/2844 ER -
Dc Identifier Vancouvercitation
Koller IM. Locking plates for distal femur fractures does an increased working length improve healing?. [Thesis]. University of Cape Town ,Faculty of Health Sciences ,Division of Orthopaedic Surgery, 2013 [cited yyyy month dd]. Available from: http://hdl.handle.net/11427/2844

Chain of custody

source
Harvested from
University of Cape Town
Base URL
open.uct.ac.za/oai/request
Last updated
2026-11-21
Source record
OAI-PMH GetRecord
citation

Koller, Ian M. Locking plates for distal femur fractures does an increased working length improve healing?. Division of Orthopaedic Surgery, 2013. http://hdl.handle.net/11427/2844