Back to search

Department of Anaesthesia and Perioperative Medicine

Perioperative comparison of the agreement between a portable fingertip pulse oximeter vs. a conventional bedside pulse oximeter in adult patients (COMFORT trial)

Abstract

dc:description.abstract

Background: Low-cost, portable fingertip pulse oximeters are widely available to health professionals and the public. They are often not tested to ISO standards, or only undergo accuracy studies in healthy volunteers under ideal laboratory conditions. This study aims to pragmatically evaluate the agreement between one such device and a conventional bedside pulse oximeter in a clinical setting, in patients with varied comorbidities and skin pigmentations. Methods: A single-centre equipment comparison study was conducted. Simultaneous measurements were obtained in 220 patients with both a Contec CMS50D Fingertip Pulse Oximeter and a Nihon Kohden Life Scope MU-631 RK conventional bedside monitor. Peripheral oxygen saturations (SpO₂) and pulse rates were documented, and patient skin tone was recorded using the Fitzpatrick scale. Data was assessed using a Bland-Altman analysis with bias, precision and limits of agreement (LOA) calculated with 95% confidence intervals. A priori acceptability for LOA was determined to be 3%, in keeping with international standards. Results: Mean difference (therefore bias) between the conventional and fingertip oximeters for all data was -0,55% (95% CI -0,73 to -0,36%). Upper and lower limits of agreement (95% CI) were 2,16 (1,84 to 2,47) and -3,25 (-3,56 to -2,94) %. Regression analysis demonstrated worsening agreement with decreasing SpO₂. When samples were separated into “normal” (SpO₂ ≥ 93%) and “hypoxaemic” (SpO₂ < 93%) groups, the normal range displayed acceptable agreement between the two oximeters (bias -0,20 with LOA 2,20 to -2,27%), while the hypoxaemic group fell outside the study’s a priori limits. Heart rate measurements had mean difference (LOA) of -0,43 (-5,61 to 4,76) beats per minute. The study was not powered to detect difference among the skin tones, but demonstrated no trend for this parameter to alter the SpO₂ measurements. Conclusions: During normoxia, portable fingertip pulse oximeters are reliable indicators of SpO₂ and pulse rates in patients with various comorbidities in a pragmatic clinical context. However, they display worsening agreement with conventional pulse oximeters during hypoxaemia. Skin tones do not appear to adversely affect measurements.

Degree

thesis:*
Grantor dc:publisher.institution
Department of Anaesthesia and Perioperative Medicine
Year dc:date.issued
2018

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Smith, Reuben Nathanael
Advisor dc:contributor.advisor
  • Hofmyer, Ross

Subjects

dc:subject × 1

Rights

Language dc:language.iso
eng

Identifiers

dc:identifier.*
Dc Identifier Apacitation
Smith, R. N. (2018). <i>Perioperative comparison of the agreement between a portable fingertip pulse oximeter vs. a conventional bedside pulse oximeter in adult patients (COMFORT trial)</i>. (). University of Cape Town ,Faculty of Health Sciences ,Department of Anaesthesia and Perioperative Medicine. Retrieved from http://hdl.handle.net/11427/29680
Dc Identifier Chicagocitation
Smith, Reuben Nathanael. <i>"Perioperative comparison of the agreement between a portable fingertip pulse oximeter vs. a conventional bedside pulse oximeter in adult patients (COMFORT trial)."</i> ., University of Cape Town ,Faculty of Health Sciences ,Department of Anaesthesia and Perioperative Medicine, 2018. http://hdl.handle.net/11427/29680
Dc Identifier Citation
Smith, R. 2018. Perioperative comparison of the agreement between a portable fingertip pulse oximeter vs. a conventional bedside pulse oximeter in adult patients (COMFORT trial). University of Cape Town.
Dc Identifier Ris
TY - Thesis / Dissertation AU - Smith, Reuben Nathanael AB - Background: Low-cost, portable fingertip pulse oximeters are widely available to health professionals and the public. They are often not tested to ISO standards, or only undergo accuracy studies in healthy volunteers under ideal laboratory conditions. This study aims to pragmatically evaluate the agreement between one such device and a conventional bedside pulse oximeter in a clinical setting, in patients with varied comorbidities and skin pigmentations. Methods: A single-centre equipment comparison study was conducted. Simultaneous measurements were obtained in 220 patients with both a Contec CMS50D Fingertip Pulse Oximeter and a Nihon Kohden Life Scope MU-631 RK conventional bedside monitor. Peripheral oxygen saturations (SpO₂) and pulse rates were documented, and patient skin tone was recorded using the Fitzpatrick scale. Data was assessed using a Bland-Altman analysis with bias, precision and limits of agreement (LOA) calculated with 95% confidence intervals. A priori acceptability for LOA was determined to be 3%, in keeping with international standards. Results: Mean difference (therefore bias) between the conventional and fingertip oximeters for all data was -0,55% (95% CI -0,73 to -0,36%). Upper and lower limits of agreement (95% CI) were 2,16 (1,84 to 2,47) and -3,25 (-3,56 to -2,94) %. Regression analysis demonstrated worsening agreement with decreasing SpO₂. When samples were separated into “normal” (SpO₂ ≥ 93%) and “hypoxaemic” (SpO₂ < 93%) groups, the normal range displayed acceptable agreement between the two oximeters (bias -0,20 with LOA 2,20 to -2,27%), while the hypoxaemic group fell outside the study’s a priori limits. Heart rate measurements had mean difference (LOA) of -0,43 (-5,61 to 4,76) beats per minute. The study was not powered to detect difference among the skin tones, but demonstrated no trend for this parameter to alter the SpO₂ measurements. Conclusions: During normoxia, portable fingertip pulse oximeters are reliable indicators of SpO₂ and pulse rates in patients with various comorbidities in a pragmatic clinical context. However, they display worsening agreement with conventional pulse oximeters during hypoxaemia. Skin tones do not appear to adversely affect measurements. DA - 2018 DB - OpenUCT DP - University of Cape Town LK - https://open.uct.ac.za PB - University of Cape Town PY - 2018 T1 - Perioperative comparison of the agreement between a portable fingertip pulse oximeter vs. a conventional bedside pulse oximeter in adult patients (COMFORT trial) TI - Perioperative comparison of the agreement between a portable fingertip pulse oximeter vs. a conventional bedside pulse oximeter in adult patients (COMFORT trial) UR - http://hdl.handle.net/11427/29680 ER -
Dc Identifier Vancouvercitation
Smith RN. Perioperative comparison of the agreement between a portable fingertip pulse oximeter vs. a conventional bedside pulse oximeter in adult patients (COMFORT trial). []. University of Cape Town ,Faculty of Health Sciences ,Department of Anaesthesia and Perioperative Medicine, 2018 [cited yyyy month dd]. Available from: http://hdl.handle.net/11427/29680

Chain of custody

source
Harvested from
University of Cape Town
Base URL
open.uct.ac.za/oai/request
Last updated
2026-11-26
Source record
OAI-PMH GetRecord
citation

Smith, Reuben Nathanael. Perioperative comparison of the agreement between a portable fingertip pulse oximeter vs. a conventional bedside pulse oximeter in adult patients (COMFORT trial). Department of Anaesthesia and Perioperative Medicine, 2018. https://hdl.handle.net/11427/29680