Back to search

Department of Electrical Engineering

The effect of steam generator tube plugging on its overall thermal performance - A Systems CFD-Based Study

Abstract

dc:description.abstract

The steam generator in a pressurized water reactor power plant acts as a fission product barrier between primary and secondary system. Material failure of the tube bundle barrier could therefore lead to a release of radioactive product into the secondary side. Several repair methods have been used to address tube leakage, with the most popular being tube plugging. The objective of this study was to quantify the effect of tube plugging on the thermal performance of a steam generator. For this purpose, the systems computational fluid dynamics (CFD) software Flownex® was used. First, a Flownex® model of the steam generator was developed and validated via comparison of the results to a validated model from the literature. Following this, a hydro-thermal analysis was performed to determine the effect of the tube plugging on the thermal performance under normal operational conditions (excluding the possibility of a tube rupture). Tube plugging of up to 20% was investigated. The model predicted the following effects: decrease in heat transfer, primary coolant mass flowrate and primary outlet pressure. Further, primary flow velocity, pressure drop and outlet temperature increase with increasing tube plugging. On the secondary side, tube plugging lowers the mixture quality in the boiling region and steam production while the re-circulation ratio was increased. Lastly, the model predicted a plugging ratio limit of 17.3%. Beyond this point, the steam generator does not extract sufficient heat from the reactor at 100% power.

Degree

thesis:*
Grantor
Department of Electrical Engineering
Year dc:date.issued
2019

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Ntuli, Japhet Mkhipheni Ali
Advisor dc:contributor.advisor
  • Malan, Arnaud

Subjects

dc:subject × 1

Rights

Language dc:language.rfc3066
eng

Identifiers

dc:identifier.*
Dc Identifier Apacitation
Ntuli, J. M. A. (2019). <i>The effect of steam generator tube plugging on its overall thermal performance - A Systems CFD-Based Study</i>. (). ,Engineering and the Built Environment ,Department of Electrical Engineering. Retrieved from http://hdl.handle.net/11427/30888
Dc Identifier Chicagocitation
Ntuli, Japhet Mkhipheni Ali. <i>"The effect of steam generator tube plugging on its overall thermal performance - A Systems CFD-Based Study."</i> ., ,Engineering and the Built Environment ,Department of Electrical Engineering, 2019. http://hdl.handle.net/11427/30888
Dc Identifier Citation
Ntuli, J. 2019. The effect of steam generator tube plugging on its overall thermal performance - A Systems CFD-Based Study.
Dc Identifier Ris
TY - Thesis / Dissertation AU - Ntuli, Japhet Mkhipheni Ali AB - The steam generator in a pressurized water reactor power plant acts as a fission product barrier between primary and secondary system. Material failure of the tube bundle barrier could therefore lead to a release of radioactive product into the secondary side. Several repair methods have been used to address tube leakage, with the most popular being tube plugging. The objective of this study was to quantify the effect of tube plugging on the thermal performance of a steam generator. For this purpose, the systems computational fluid dynamics (CFD) software Flownex® was used. First, a Flownex® model of the steam generator was developed and validated via comparison of the results to a validated model from the literature. Following this, a hydro-thermal analysis was performed to determine the effect of the tube plugging on the thermal performance under normal operational conditions (excluding the possibility of a tube rupture). Tube plugging of up to 20% was investigated. The model predicted the following effects: decrease in heat transfer, primary coolant mass flowrate and primary outlet pressure. Further, primary flow velocity, pressure drop and outlet temperature increase with increasing tube plugging. On the secondary side, tube plugging lowers the mixture quality in the boiling region and steam production while the re-circulation ratio was increased. Lastly, the model predicted a plugging ratio limit of 17.3%. Beyond this point, the steam generator does not extract sufficient heat from the reactor at 100% power. DA - 2019 DB - OpenUCT DP - University of Cape Town KW - Engineering LK - https://open.uct.ac.za PY - 2019 T1 - The effect of steam generator tube plugging on its overall thermal performance - A Systems CFD-Based Study TI - The effect of steam generator tube plugging on its overall thermal performance - A Systems CFD-Based Study UR - http://hdl.handle.net/11427/30888 ER -
Dc Identifier Vancouvercitation
Ntuli JMA. The effect of steam generator tube plugging on its overall thermal performance - A Systems CFD-Based Study. []. ,Engineering and the Built Environment ,Department of Electrical Engineering, 2019 [cited yyyy month dd]. Available from: http://hdl.handle.net/11427/30888

Chain of custody

source
Harvested from
University of Cape Town
Base URL
open.uct.ac.za/oai/request
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
related terms
citation

Ntuli, Japhet Mkhipheni Ali. The effect of steam generator tube plugging on its overall thermal performance - A Systems CFD-Based Study. Department of Electrical Engineering, 2019. https://hdl.handle.net/11427/30888