Department of Civil Engineering
The static and fatigue behavior of low profile precast concrete sleepers
Abstract
dc:description.abstractLow Profile precast concrete sleepers have the same vertical dimension as traditional wooden sleepers and thus offer a promising alternative to replace wooden sleepers on tracks where maintaining vertical alignment is necessary. The structural response of Low Profile precast concrete sleepers was studied under static and fatigue loading regimes using a tuned finite element model and four point flexure laboratory tests. The fatigue tests were conducted by following the procedure specified in the Australian railway code (AS 1084.14-2012). The usefulness of the Australian code fatigue test was brought into question as the fatigue life of Low Profile sleepers far exceeded the 3 million load cycle specified by the code. This study concluded that Low Profile concrete sleepers have excessive fatigue resistance however the limiting design criteria for Low Profile sleepers should be governed by a serviceability approach in order to limit cracking and thus ensure an adequate durability life span.
Degree
thesis:*- Grantor
- Department of Civil Engineering
- Year dc:date.issued
- 2019
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Goodhead, Andrew H
- Advisor dc:contributor.advisor
-
- Moyo, Pilate
Subjects
dc:subject × 1Rights
- Language dc:language.rfc3066
- eng
Identifiers
dc:identifier.*- Dc Identifier Apacitation
- Goodhead, A. H. (2019). <i>The static and fatigue behavior of low profile precast concrete sleepers</i>. (). ,Engineering and the Built Environment ,Department of Civil Engineering. Retrieved from http://hdl.handle.net/11427/31512
- Dc Identifier Chicagocitation
- Goodhead, Andrew H. <i>"The static and fatigue behavior of low profile precast concrete sleepers."</i> ., ,Engineering and the Built Environment ,Department of Civil Engineering, 2019. http://hdl.handle.net/11427/31512
- Dc Identifier Citation
- Goodhead, A.H. 2019. The static and fatigue behavior of low profile precast concrete sleepers. . ,Engineering and the Built Environment ,Department of Civil Engineering. http://hdl.handle.net/11427/31512
- Dc Identifier Ris
- TY - Thesis / Dissertation AU - Goodhead, Andrew H AB - Low Profile precast concrete sleepers have the same vertical dimension as traditional wooden sleepers and thus offer a promising alternative to replace wooden sleepers on tracks where maintaining vertical alignment is necessary. The structural response of Low Profile precast concrete sleepers was studied under static and fatigue loading regimes using a tuned finite element model and four point flexure laboratory tests. The fatigue tests were conducted by following the procedure specified in the Australian railway code (AS 1084.14-2012). The usefulness of the Australian code fatigue test was brought into question as the fatigue life of Low Profile sleepers far exceeded the 3 million load cycle specified by the code. This study concluded that Low Profile concrete sleepers have excessive fatigue resistance however the limiting design criteria for Low Profile sleepers should be governed by a serviceability approach in order to limit cracking and thus ensure an adequate durability life span. DA - 2019 DB - OpenUCT DP - University of Cape Town KW - Civil Engineering LK - https://open.uct.ac.za PY - 2019 T1 - The static and fatigue behavior of low profile precast concrete sleepers TI - The static and fatigue behavior of low profile precast concrete sleepers UR - http://hdl.handle.net/11427/31512 ER -
- Dc Identifier Vancouvercitation
- Goodhead AH. The static and fatigue behavior of low profile precast concrete sleepers. []. ,Engineering and the Built Environment ,Department of Civil Engineering, 2019 [cited yyyy month dd]. Available from: http://hdl.handle.net/11427/31512