Back to search

Department of Physics

Development of an ion transport system for singly charged ion injection into an electron string ion source (ESIS) charge-breeder

Abstract

dc:description.abstract

A 1+ ion delivery system was designed and constructed for the purpose of ion injection into the Electron String Ion Source (ESIS) charge-breeder at the Joint Institute for Nuclear Research (JINR) in Dubna, Russia. The transport system was initially developed at iThemba LABS in Cape Town. This system includes a Liquid Metal Ion Source (LMIS) and an ion extraction and focusing system. The ion delivery system is used to produce Ga+ and Au+ ions which are transported through a beam-line system consisting of charged particle optics such as focusing einzel-lenses, an electrical quadrupole switchyard for 90◦ beam bending, and subsequent correction and focusing lenses before the entry port into the ESIS. A replica of the full system was created and used to study injection and ion transport efficiency before implementation with the ESIS. A multi-wire harp beam profilometer was used to study ion beam profiles and to obtain geometric parameters of Ga+ beams. Ga+ injection into the KRION 6T ESIS was performed successfully using the ion injection system. The extraction of multiply charged gallium was successful after 1+ injection into the KRION 6T ESIS, with a maximum charge-state of 23+. Although 1+ to n+ injection has been performed with similar Electron Beam Ion Source (EBIS) devices, this work is the first case of 1+ to n+ injection using the ESIS. This research was conducted within the frame-work of the South Africa/JINR collaboration and has been funded by the National Research Foundation (NRF).

Degree

thesis:*
Grantor
Department of Physics
Year dc:date.issued
2020

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Segal, Matthew
Advisor dc:contributor.advisor
  • Peterson, Steve

Subjects

dc:subject × 1

Rights

Language dc:language.rfc3066
eng

Identifiers

dc:identifier.*
Dc Identifier Apacitation
Segal, M. (2020). <i>Development of an ion transport system for singly charged ion injection into an electron string ion source (ESIS) charge-breeder</i>. (). ,Faculty of Science ,Department of Physics. Retrieved from http://hdl.handle.net/11427/33024
Dc Identifier Chicagocitation
Segal, Matthew. <i>"Development of an ion transport system for singly charged ion injection into an electron string ion source (ESIS) charge-breeder."</i> ., ,Faculty of Science ,Department of Physics, 2020. http://hdl.handle.net/11427/33024
Dc Identifier Citation
Segal, M. 2020. Development of an ion transport system for singly charged ion injection into an electron string ion source (ESIS) charge-breeder. . ,Faculty of Science ,Department of Physics. http://hdl.handle.net/11427/33024
Dc Identifier Ris
TY - Doctoral Thesis AU - Segal, Matthew AB - A 1+ ion delivery system was designed and constructed for the purpose of ion injection into the Electron String Ion Source (ESIS) charge-breeder at the Joint Institute for Nuclear Research (JINR) in Dubna, Russia. The transport system was initially developed at iThemba LABS in Cape Town. This system includes a Liquid Metal Ion Source (LMIS) and an ion extraction and focusing system. The ion delivery system is used to produce Ga+ and Au+ ions which are transported through a beam-line system consisting of charged particle optics such as focusing einzel-lenses, an electrical quadrupole switchyard for 90◦ beam bending, and subsequent correction and focusing lenses before the entry port into the ESIS. A replica of the full system was created and used to study injection and ion transport efficiency before implementation with the ESIS. A multi-wire harp beam profilometer was used to study ion beam profiles and to obtain geometric parameters of Ga+ beams. Ga+ injection into the KRION 6T ESIS was performed successfully using the ion injection system. The extraction of multiply charged gallium was successful after 1+ injection into the KRION 6T ESIS, with a maximum charge-state of 23+. Although 1+ to n+ injection has been performed with similar Electron Beam Ion Source (EBIS) devices, this work is the first case of 1+ to n+ injection using the ESIS. This research was conducted within the frame-work of the South Africa/JINR collaboration and has been funded by the National Research Foundation (NRF). DA - 2020_ DB - OpenUCT DP - University of Cape Town KW - Physics LK - https://open.uct.ac.za PY - 2020 T1 - Development of an ion transport system for singly charged ion injection into an electron string ion source (ESIS) charge-breeder TI - Development of an ion transport system for singly charged ion injection into an electron string ion source (ESIS) charge-breeder UR - http://hdl.handle.net/11427/33024 ER -
Dc Identifier Vancouvercitation
Segal M. Development of an ion transport system for singly charged ion injection into an electron string ion source (ESIS) charge-breeder. []. ,Faculty of Science ,Department of Physics, 2020 [cited yyyy month dd]. Available from: http://hdl.handle.net/11427/33024

Chain of custody

source
Harvested from
University of Cape Town
Base URL
open.uct.ac.za/oai/request
Last updated
2026-11-27
Source record
OAI-PMH GetRecord
related terms
citation

Segal, Matthew. Development of an ion transport system for singly charged ion injection into an electron string ion source (ESIS) charge-breeder. Department of Physics, 2020. https://hdl.handle.net/11427/33024