Division of General Surgery
Does the Intra-operatively measured Leg Length Correction compare to the Post-operative radiograph in Total Hip Replacement surgery?
Abstract
dc:description.abstractAims This study aims to compare the leg length correction (LLC) measured intra-operatively using the Vertical Measurement SystemTM (VMS) in total hip arthroplasty (THA), with the LLC measured on a 6-week post-operative Xray. We also wanted to quantify any residual leg length discrepancy (LLD) using this method. Patients and Methods A prospective cohort study was conducted, in which patients undergoing primary THA were enrolled at two centres in Cape Town, over a period of 19 weeks. THA's were performed by four surgeons. Pre-operative leg length discrepancy measurements were obtained in 92 patients. The VMS was used to predict intra-operative leg length correction (LLC), and this measurement was compared to the post-operative leg length correction measured on the 6-week follow-up X-ray. These measurements were statistically compared using Mann-Whitney U Test. Results The difference between the intra-operative VMS calculation and the 6-week radiological measurement was not significant (p>0.05), with the difference in their mean values being 0.07 ± 3.26mm. In the cohort, 81.52% of the patients (n=75) were within 5mm of the target LLC, and 95.65% of patients (n=88) were within 10mm of the target LLC. The mean absolute residual LLD at 6 weeks was 3.22 ± 3.13mm. Conclusion The intra operative LLC measurement obtained using the VMS accurately predicts the 6-week post op radiographic LLC measurement.
Degree
thesis:*- Grantor
- Division of General Surgery
- Year dc:date.issued
- 2021
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Moonda, Zaheer
- Advisor dc:contributor.advisor
-
- Nortjie, Marc
Subjects
dc:subject × 1Rights
- Language dc:language.rfc3066
- eng
Identifiers
dc:identifier.*- Dc Identifier Apacitation
- Moonda, Z. (2021). <i>Does the Intra-operatively measured Leg Length Correction compare to the Post-operative radiograph in Total Hip Replacement surgery?</i>. (). ,Faculty of Health Sciences ,Division of General Surgery. Retrieved from http://hdl.handle.net/11427/33852
- Dc Identifier Chicagocitation
- Moonda, Zaheer. <i>"Does the Intra-operatively measured Leg Length Correction compare to the Post-operative radiograph in Total Hip Replacement surgery?."</i> ., ,Faculty of Health Sciences ,Division of General Surgery, 2021. http://hdl.handle.net/11427/33852
- Dc Identifier Citation
- Moonda, Z. 2021. Does the Intra-operatively measured Leg Length Correction compare to the Post-operative radiograph in Total Hip Replacement surgery?. . ,Faculty of Health Sciences ,Division of General Surgery. http://hdl.handle.net/11427/33852
- Dc Identifier Ris
- TY - Master Thesis AU - Moonda, Zaheer AB - Aims This study aims to compare the leg length correction (LLC) measured intra-operatively using the Vertical Measurement SystemTM (VMS) in total hip arthroplasty (THA), with the LLC measured on a 6-week post-operative Xray. We also wanted to quantify any residual leg length discrepancy (LLD) using this method. Patients and Methods A prospective cohort study was conducted, in which patients undergoing primary THA were enrolled at two centres in Cape Town, over a period of 19 weeks. THA's were performed by four surgeons. Pre-operative leg length discrepancy measurements were obtained in 92 patients. The VMS was used to predict intra-operative leg length correction (LLC), and this measurement was compared to the post-operative leg length correction measured on the 6-week follow-up X-ray. These measurements were statistically compared using Mann-Whitney U Test. Results The difference between the intra-operative VMS calculation and the 6-week radiological measurement was not significant (p>0.05), with the difference in their mean values being 0.07 ± 3.26mm. In the cohort, 81.52% of the patients (n=75) were within 5mm of the target LLC, and 95.65% of patients (n=88) were within 10mm of the target LLC. The mean absolute residual LLD at 6 weeks was 3.22 ± 3.13mm. Conclusion The intra operative LLC measurement obtained using the VMS accurately predicts the 6-week post op radiographic LLC measurement. DA - 2021_ DB - OpenUCT DP - University of Cape Town KW - Orthopaedic Surgery LK - https://open.uct.ac.za PY - 2021 T1 - Does the Intra-operatively measured Leg Length Correction compare to the Post-operative radiograph in Total Hip Replacement surgery? TI - Does the Intra-operatively measured Leg Length Correction compare to the Post-operative radiograph in Total Hip Replacement surgery? UR - http://hdl.handle.net/11427/33852 ER -
- Dc Identifier Vancouvercitation
- Moonda Z. Does the Intra-operatively measured Leg Length Correction compare to the Post-operative radiograph in Total Hip Replacement surgery?. []. ,Faculty of Health Sciences ,Division of General Surgery, 2021 [cited yyyy month dd]. Available from: http://hdl.handle.net/11427/33852